1.5 Viscosity-pressure diagram
The appropriate valve plug is selected in accordance
with this diagram. In the case of different operating
parameters, please consult Richter.
2
Notes on safety
This operating manual contains fundamental
information which is to be observed during installation,
operation and maintenance.
It must be read before installation and
commissioning!
For valves which are used in potentially explosive ar-
eas, see
Section 3
.
Installation, operation and maintenance are to be per-
formed by qualified staff.
The area of responsibility, authority and supervision of
the staff must be regulated by the customer.
General hazard symbol!
People may be put at risk.
Safety symbol!
The ball valve and its
function may be put at risk if this safety
symbol is not observed.
It is imperative to observe warnings and signs attached
directly to the ball valve and they are to be kept fully
legible.
Non-observance of the notes on safety may result
in the loss of any and all claims for damages.
For example, non-observance may involve the follow-
ing hazards:
♦
Failure of important functions of the valve/plant.
♦
Risk to people from electric, mechanical and chem-
ical effects.
♦
Risk to the environment through leaks of hazardous
substances.
2.1 Intended use
Richter sampling valves are pressure-maintaining com-
ponents in accordance with the Pressure Equipment
Directive (DGRL) for taking liquid samples.
The standard PA/F and PA/S are only intended for hor-
izontal installation (vertical installation only with special
adapter).
The valves are suitable for non-boiling liquids of group
1 in acc. with the Pressure Equipment Directive
(DGRL).
Solids
can lead to increased wear, damage to sealing
surfaces or to a reduction in the service life of the valve.
In case of the valve is intended for operating data other
than those intended, the customer must carefully ex-
amine whether the design of the valve, accessories and
materials are suitable for the new application. (Please
consult the manufacturer).