background image

Series   KNA/F, KNAP/F, 

KNA-D/F, KNAP-D/F,

 

Page 3 

 

KNA-S, KNAP-S, 

ASME

 

 

9520-080-en_USA 

Revision  15 

TM 9549

 

Edition  07/2016 

Relevant documents 

  Declaration of conformity acc. to the EC Pressure 

Equipment Directive 2014/68/EU 

  Manufacturer’s  Declaration  German  Clean  Air  Act 

(TA-Luft) 

  Manufacturer’s Declaration SIL 

  Form  for  Safety  Information  Concerning  the 

Contamination QM 0912-16-2001_en 

  For KNAP/F, KNAP-D/F, KNAP-S/F:  

Operating manual for actuator  

  Depending on option, relevant drawing: 

Double packing bonnet, 

Section  

9520-00-3001

 

 

Dimen. 

9520-00-4011

 

Extended stem, 

Section 

9520-00-3009

 

DN 50-100 

Dimen. 

9520-00-4022

 

Extended stem, 

Section 

9520-00-3003

 

DN 150-200 

Dimen. 

9520-00-4013

 

Extended stem, round 

Section  

9520-00-3010

 

 

Dimen. 

9520-00-4020

 

Lever elevation 

Section  

9520-00-3011

 

 

Dimen. 

9520-00-4021

 

Limit switch IFM 

Section  

9520-00-3005

 

 

Dimen. 

9520-00-4015

 

Spring return unit Kinetrol 

Section  

9520-00-3004

 

 

Dimen. 

9520-00-4014

 

Limit switch VDE/VDI 

Section  

9520-00-3006

 

 

Dimen. 

9520-00-4016

 

Initiator Turck 

Schnitt  

9520-00-3007

 

 

Dimen. 

9520-00-4017

 

Heating jacket 

 

9520-00-3012

 

Change from manual operation 

to power operation 

Dimen. 

9520-00-4018 

 

 

 

 

 

 

1  Technical data 

Manufacturer: 

Richter Chemie-Technik GmbH 

Otto-Schott-Str. 2 

D-47906 Kempen 

Telephone:  +49 (0) 2152 146-0 

Fax:  

  +49 (0) 2152 146-190 

E-Mail:    

[email protected]

 

Internet:    

http://www.richter-ct.com

 

Designation : 

Ball  valve  with  one-piece  ball/stem  unit  with  plastic 

coating,  Al

2

O

3

-ball  and  stem,  full  port,  maintenance-

free  self-adjusting  Richter  ENVIPACK  universal 

packing,  seat  rings  of  pure  PTFE,  cavity  reduced  as 

standard feature, two-piece body.  
Series: 

KNA/F 

 

 Design with lever or hand gear  

KNAP/F

 

 Design  prepared  for  pneum.,  hydr.  or 

electric actuator to ISO 5211 

KNA-D/F

  

 KNA/F with thick-walled (5mm) body 

lining 

KNAP-D/F

 

 KNAP/F with thick-walled (5mm) body 

lining 

KNA-S/F

  

 Design stainless steel with lever,  

 

    FDA conform wetted materials 

KNAP-S/F

 

 Design  stainless  steel  prepared  for 

pneum.,  hydr.  or  electric  actuator  to 

ISO 5211 

Certified to German Clean Air Act (TA Luft) 
MSS SP 72  

General Service 

MSS SP 25  

Standard Marketing System 

API 598 Valve Inspection and Testing 

 

The  tests  at  Richter  fulfils  the  requirements 

 

of API 598 on principle. However this  

 

standard  contains  optional,  additional  tests. 

 

These  tests  are  not  object  of  the  tests  at 

 

Richter  and  have  to  be  arranged  by  order 

 

with  Richter  (e.g.  point  3.3:  High  Pressure 

 

Closure Test). 

Face to face:  ASME B16.10, Class 150  

 

to 6” 

column 19 

 

8“/6“, 8“  column 18 

Flange connecting dimensions:  

ASME B16.5 Class 150, raised face. 

Materials : 

Body material:  

KNA/F, KNAP/F, KNA-D/F, KNAP-D/F: 

Ductile cast iron ASTM A395 / EN-JS 1049 
KNA-S/F, KNAP-S/F

:

 

316 investment cast, CF8M (1.4408) 
Lining material: PFA/PTFE 

.../F 

On request: 

antistatic 

…/F-L 

Temperature range : 

See pressure-temperature diagram in Chapter 1.6. 

Operating pressure:  

½“ – 6“   from vacuum  to max.245 psig (17 bar) 
8”/6”, 8“ from vacuum   to max.145 psig (10 bar) 

to ASME B16.42 
See pressure-temperature diagram in Chapter 1.6. 

Summary of Contents for BVA Series

Page 1: ...te the valves beyond the stated pressure and temperature ratings Misuse improper installation and improper maintenance may result in personal injury and or property damage Use only valve components co...

Page 2: ...enance 12 9 1 Dismantling ball valve with ball stem unit 12 9 1 1 Ball valve with lever 12 9 1 2 Packing bellows 12 9 1 3 Ball valve with actuator 12 9 2 Assembly with ball stem unit 12 9 2 1 Packing...

Page 3: ...h one piece ball stem unit with plastic coating Al2O3 ball and stem full port maintenance free self adjusting Richter ENVIPACK universal packing seat rings of pure PTFE cavity reduced as standard feat...

Page 4: ...g components Ball stem unit Al2O3 ball stem Options Richter ENVIPACK double packing for particularly high safety requirements self adjusting On request monitoring and flushing connection Ball stem uni...

Page 5: ...2 35 310 4 x M12 35 310 1 4 x M12 35 310 1 4 x M16 45 400 2 4 x M16 45 400 3 6 x M16 50 445 4 6 x M20 60 531 6 8 x M20 150 1335 8 6 8 x M20 150 1330 8 12 x M24 175 1549 1 4 Breakaway torques Test medi...

Page 6: ...07 2016 1 6 Pressure temperature diagram When used in the area of application of ASME the low temperature of ASTM A395 is limited to 20 F 29 C When used in the minus temperature range the regulations...

Page 7: ...t off of fluids The valves are suitable for vapours gases and non boiling liquids of group 1 according to the PED and have a corrosion resistant plastic lining Solids can lead to increased wear damage...

Page 8: ...uation and filling the formation of an explosive atmosphere must be prevented e g by superimposing a layer of nitrogen It is recommended to wait 1 hour before removing the valve from the plant in orde...

Page 9: ...tilated room at as constant a temperature as possible Elastomers are to be protected against UV light In general a storage period of 10 years should not be exceeded 5 2 Return consignments Valves whic...

Page 10: ...om the Richter product range 6 2 Direction of flow and installation position Installation is independent of the direction of flow Any installation position can be chosen Otherwise it is marked by a di...

Page 11: ...age 7 3 Shutdown The local regulations are to be observed when dismantling the valve Prior to undoing the flange connection ensure that the plant is depressurised and emtied Prior to starting any repa...

Page 12: ...ibed in Chapter 9 1 1 and 9 1 2 9 2 Assembly with ball stem unit Prior to assembly all parts are to be cleaned and the plastic lined components checked for damage Insert seat rings 401 in the main bod...

Page 13: ...aned and the plastic lined components checked for damage Insert seat rings 401 in the main body 101 and body end piece 102 Insert stem 202 from inside into the main body 101 In the case of 6 and 8 6 w...

Page 14: ...nce with the actua tor operating manual Mounting dimensions see drawing 9520 00 4018 10 Drawings 10 1 Legend 101 main body 102 body end piece 200 ball 201 ball stem unit 202 stem 203 lever lockable 40...

Page 15: ...15 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 2 Sectional drawing ball valve with ball stem unit and lever 10 2 1 Ball valve with ball stem unit and lever 8 6 Holes of th...

Page 16: ...Series KNA F KNAP F KNA D F KNAP D F Page 16 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 2 2 Ball valve with ball stem unit and worm gear 8...

Page 17: ...KNAP F KNA D F KNAP D F Page 17 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 2 3 Ball valve with ball stem unit and actuator Holes of the flange and housing screws view dis...

Page 18: ...A F KNAP F KNA D F KNAP D F Page 18 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 2 4 Ball valve with ball stem and lever Holes of the flange and housing screws view displac...

Page 19: ...KNA D F KNAP D F Page 19 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 2 5 Sectional drawing ball valve with ball stem and actuator Holes of the flange and housing screws v...

Page 20: ...3 View and section ball valve with lever View Z Section B B Tighten packing gland follower 503 until spring gland follower 502 is in contact without any gap 10 4 Sections ball valve with actuator Sec...

Page 21: ...56 75 81 94 107 130 223 5 228 5 HL inch 7 05 10 2 16 1 20 17 mm 179 259 410 512 5 H inch 4 94 6 29 6 39 8 09 8 72 11 18 mm 125 5 159 5 162 5 205 5 221 5 284 H1 inch 1 97 3 03 3 14 4 64 5 27 7 24 9 33...

Page 22: ...Series KNA F KNAP F KNA D F KNAP D F Page 22 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 5 2 Ball valve with gear 8...

Page 23: ...F KNAP F KNA D F KNAP D F Page 23 KNA S KNAP S ASME 9520 080 en_USA Revision 15 TM 9549 Edition 07 2016 10 5 3 Ball valve with actuator Dimensions H3 H4 L1 L2 and L3 vary depending on the actuator ma...

Page 24: ...69 74 112 130 180 238 B1 inch 4 29 5 43 5 82 9 44 11 81 14 96 17 32 mm 109 138 148 240 300 380 440 port inch 0 59 0 79 0 96 1 50 1 87 3 07 3 78 5 71 5 71 7 68 mm 15 20 24 5 38 37 5 78 96 145 145 195...

Page 25: ......

Page 26: ...er Betriebsanleitung Insbesondere sind regelm ige Wartungsintervalle durchzuf hren und die dichtheitsrelevanten Schraubverbindungen zu berpr fen und wenn notwendig nachzuziehen meets the requirement r...

Page 27: ...129 FIT SD 14 FIT DU 108 FIT DD 36 FIT SFF 62 5 PFDAvg 4 73 10 4 for TProof 1 year MTBF 398 years Safety Intigrity Level SIL 2 Usable lifetime According to IEC 61508 2 7 4 7 4 values of up to 10 years...

Page 28: ...tamination of the pumps valves and component sent in for repair On the basis of this information for the contractor is it possible to meet the necessary preventive action during the execution of the r...

Page 29: ...hich cleaning method radioactive 3 1 if no then forward to D other pollutant 2 Aggregates which are contaminated with microbiological or explosive substances are only accepted with documented evidence...

Page 30: ...spection repair of Richter products and parts will only take place if the attached explanation is filled out correctly and completely by authorized and qualified technical personnel and is available I...

Reviews: