Beijing RuiZhitianhong technology Co.Ltd.
ADD.
:
A308 jiahua building,
9 Shangdi 3rd Street, Haidian District, Beijing.
P.C.
:
100085.
Dell
:
+86-10-62970368/82923063 Fax
:
+86-10-82920078 URL
:
www.richnc.com.cn
31
The speed of axis started directly from standstill. Not starting from zero speed,
but starting directly from a certain speed,so it can shorten the overall processing
time,but do not set this speed too high. Set too high, it will cause the motor losing
steps, jitter and even whistle;Set too small, it will reduce the operating speed of the
entire graph. If the inertia of motion axes (axis heavier), users can set a smaller start
speed, if the inertia of motion axes smaller (lighter shaft), users can set it bigger.
Setting
:
Enter
“
Start Speed
”,
screen shows:
Press “
” and input the new number
,
press “
” to save.
7. Voltage Setup
:
Set input and output signal terminal status
,
lights green indicate normally open
state, lights red indicate normally closed state.Including the two rows of light:
The upper lights indicate the input level
:
Set input voltage signal terminal
status.The top four: 0
、
1
、
2
、
3 positions correspond X axis back home
、
Y axis back
home
、
Z axis back home
、
toolsetting signal.
The under lights indicate the input level
:
Set output voltage signal terminal
status. The top four: 0
、
1
、
2
、
3 positions correspond spindleOn/Off
、
multi-speed 1
、
multi-speed 2
、
multi-speed 3 siganl.
Setting
:
Press
“
”、
“
”
to move cursor right and left
,
press
“
”、
“
”
to move cursor up and down
,
press
“
”
to change light red or green.