49
triggers
,
indicator lamp will be red
(
light
)
.it signifies that signal triggers. If signal
triggers
,
indicator lamp not light
,
you should check the corresponding signal sensor
、
circuit and interface board.
2. Guard output state
:
OUTPUT SIGNAL terminal has 01-32, total of 32 status indicator lamps, and
the interface board OUTPUT SIGNAL terminal Y01 - Y16 one-to-one correspond to
the indicator lamps.Indicator lamp01- OUTPUT SIGNAL Y01(Spindle CW state
,
Spindle CCW state), indicator lamp02- OUTPUT SIGNAL Y02(Spindle Shift 1)
,
indicator lamp03- OUTPUT SIGNAL Y03(Spindle Shift 2)
,
indicator lamp04-
OUTPUT SIGNAL Y04(Spindle Shift 3),and other lamps correspond to other
definable signal.
User can change indicator lamp state by pressing
“
”,
to realize manually
control output signal.Press
“
”、“
”
to move cursor left and right
,
and
then press
“
”
to change indicator lamp state. For instance
:If
cursor stop at
indicator lamp 01
,
press
“
”
,
indicator lamp lights
(
get red
)
,
spindle on.
4.5