Tracer AV
18
Visit our website
Level 3 submenus
Primary Units (PRIMAR Parameter)
DECPNT
88888.8
888888
888880
8.88888
88.8888
888.888
8888.88
Decimal point location. Specifies the location of the decimal point or dummy zeroes in the primary unit display.
Value should be consistent with local legal requirements
DSPDIV
5D
1D
2D
Display divisions. Selects the minimum division size for the primary units displayed weight
UNITS
LB
KG
OZ
TN
T
G
NONE
Specifies primary units for displayed and printed weight. Values are: LB=pound; KG=kilogram; OZ=ounce;
TN=short ton; T=metric ton; G=gram
Note: Indicators sold outside North America are configured with
KG
for both primary and secondary
units.
Secondary Units (SECNDR Parameter)
DECPNT
88888.8
888888
888880
8.88888
88.8888
888.888
8888.88
Decimal point location. Determines the location of the decimal point or dummy zeros in the secondary unit dis
-
play
DSPDIV
5D
1D
2D
Display divisions. Selects the value of minimum division size of the displayed weight
UNITS
KG
OZ
TN
T
G
NONE
LB
Specifies secondary units for displayed and printed weight. Values are: KG=kilogram; OZ=ounce; TN=short
ton; T=metric ton; G=gram; LB=pound
MULT
0.453592
Enter other
choices via
keyboard
Multiplier. Specifies the conversion factor by which the primary units are multiplied to obtain the secondary
units. The default is 0.453592, which is the conversion factor for changing pounds to kilograms. See
Note
:
Multipliers are pre-configured within the indicator. Manual entry is only necessary when NONE is
selected under UNITS.
To toggle between primary and secondary units, press the
Units
key.
FORMAT Menu
Parameter
Choices
Description
Table 3-5. Format Menu Parameters (Continued)