30
Tracer AV Installation Manual
5.1.6
Normal Mode Commands
The serial transmit weight data commands (see Table 5-12) transmit data to the EDP port on demand. The SX
and EX commands are valid only in normal operating mode; all other commands are valid in either setup or
normal mode.
Command
Description
Response Format
UID
Set unit ID
nnnnnnn
SD
Set date
MMDDYY, DDMMYY, YYMMDD (enter using DATEFMT
specified)
ST
Set time
hhmm (enter using 24-hour format)
SX
Start EDP streaming
OK
or
??
EX
Stop EDP streaming
OK
or
??
RS
Reset system
—
XG
Transmit gross weight in displayed units
nnnnnn UU
where
nnnnnn
is the weight value,
UU
is the units.
XN
Transmit net weight in displayed units
XT
Transmit tare weight in displayed units
XG2
Transmit gross weight in non-displayed units
XN2
Transmit net weight in non-displayed units
XT2
Transmit tare weight in non-displayed units
XE
Query system error conditions
nnnnn nnnnn
See Section 6.1.2 on page 33 for detailed information about
the XE command response format.
Table 5-12. Normal Mode Commands