Tracer AV Installation Manual - Installation
9
2.4
Board Removal
If you must remove the
Tracer AV
CPU board, use the following procedure:
•
Use a wrist strap to ground yourself and protect components from electrostatic discharge (ESD) when
working inside the
Tracer AV
enclosure.
•
This unit uses line fusing which could create an electric shock hazard. Procedures requiring work inside
the
Tracer AV
enclosure must be performed by qualified service personnel only.
•
The supply cord serves as the main power disconnect for the
Tracer AV
. The power outlet must be
installed near the unit and be easily accessible.
1. Disconnect power to the
Tracer AV
.
2. Cut security cable (if installed) and remove screws.
3. Remove the top cover.
4. Disconnect power supply cable from connector J7 on the
Tracer AV
CPU board.
5. Unplug connectors J1 (load cell cable), J2 (digital inputs), J3 (EDP), J4 (serial), J6 (digital outputs), and
J2 (display). See Figure 2-4 5 for connector locations.
6. Remove the five screws from the CPU board, then lift the board out of the enclosure.
To replace the CPU board, reverse the above procedure.
2.5
Replacement Parts
Table 2-6 lists replacement parts for the
Tracer AV
.
PN
Description (Quantity)
97994
Tracer AV
Enclosure Assembly
70599
6 Pos Screw Terminal - Pluggable 5mm Center Screws (2)
71125
3 Pos Screw Terminal - Pluggable 5mm Center Screws (2)
71126
4 Pos Screw Terminal - Pluggable 5mm Center Screws(1)
76556
Power Supply (1)
87958
CPU Board Assembly (1)
97881
Coverplate - 10” x 6 ”x 2” (1)
97978
DB-9 PCB Assembly (1)
93558
Remote Display
93213
Back Cover Enclosure (1)
93215
Remote Display Lens (1)
93559
Front Panel Assembly (1)
93561
PCB Assembly (1)
93563
Cable Assembly (1)
97995
2-Button Keypad
50749
DB-9 FEM to DB-9 Cable (1)
71014
Piezo Switch SST SPSI (2)
97877
Front Switch Panel (1)
97878
Rear Switch Panel Cover (1)
97977
PCB Assembly (1)
Table 2-6. Replacement Parts