Tracer AV Installation Manual - Calibration
23
4.0
Calibration
The
Tracer AV
can be calibrated using the
Zero
and
Units
keys, EDP commands, or the
Revolution
®
configuration
utility. Each method consists of the following steps:
•
Zero calibration
•
Entering the test weight value
•
Span calibration
•
Optional rezero calibration for test weights
using hooks or other additional items.
Figure 4-1. Calibration (CALIBR) Menu
You can also use the default calibration feature, which utilizes a more user-friendly procedure; however, not all
options are available in default calibration.
Figure 4-2. Default Calibration (DEFCAL) Menu
4.1
Default Calibration
If you use a 500lb or 300lb scale, you can select it
from the
DEFCAL
menu. This automatically uses the
settings shown in Table 4-1. for 500lbs or Table 4-2.
for 300lbs.
To calibrate the
Tracer AV
using the
Zero
and
Units
keys, do the following:
1. Place the
Tracer AV
in setup mode
To enter setup mode, remove the setup switch
access screw on the
Tracer AV
4). Once the screw is removed, use a small
screwdriver to press the setup switch. The
display changes to show the word
DEFCAL
.
2. Remove all weight from the scale platform. If
your test weights require hooks or other
items, place them on the scale.
3. Press the
Zero
key to go to
SELECT
.
4. Press the
Units
key to go to zero calibration
(
WZERO
).
5. Press the
Zero
key to calibrate zero. The
indicator displays
*CAL*
while calibration is in
progress. When complete, the A/D count for
the zero calibration is displayed.
DO NOT
adjust this value after WSPAN has been set!
Press
Zero
again to save the zero calibration
value and go to the next prompt (
WVAL
).
XXXXXXX
XXXXXXX
WZERO
WV AL
WSPAN
SETPNT
PROGRM
SERIAL
CALIBR
CONFIG FORMAT
REZERO
VERS
Zero
DEFCAL
XXXXXXX
XXXXXXX
SETPNT
PROGRM
SERIAL
CALIBR
CONFIG FORMAT
VERS
XXXXXXX
DEFCAL
SELECT
WV AL
WSPAN
WZERO
500lb
300lb
Primary
500lb x 1lb
Secondary
250kg x .5kg
SP1 Trip
50lb
SP2
Off
Digital Filter
8,8,8
Zero Tracking
3D
Table 4-1. 500lb scale settings
Primary
300lb x 1lb
Secondary
150kg x .5kg
SP1 Trip
50lb
SP2
Off
Digital Filter
8,8,8
Zero Tracking
3D
Table 4-2. 300lb scale settings