Tracer AV Installation Manual - EDP Commands
27
5.1.2
Reporting Commands
Reporting commands (see Table 5-2) send specific
information to the EDP port. These commands can be
used in both setup mode and normal mode.
5.1.3
The RESETCONFIGURATION Command
The
RESETCONFIGURATION
command can be used to
restore all configuration parameters to their default
values. Before issuing this command, the
Tracer AV
must be placed in test mode (press and hold setup
switch for approximately three seconds to show TEST
menu).
This command is equivalent to using the DEFLT
function on the TEST menu. See Section 6.7 on
page 39 for more information about test mode and
using the TEST menu.
NOTE:
All load cell calibration settings are lost when the
RESETCONFIGURATION command is run.
5.1.4
Parameter Setting Commands
Parameter setting commands allow you to display or
change the current value for a particular configuration
parameter (Tables 5-3 through 5-11).
Current configuration parameter settings can be
displayed in either setup mode or normal mode using
the following syntax:
command
<ENTER>
Most parameter values can be changed in setup mode
only. Use the following command syntax when
changing parameter values:
command
=
value
<ENTER>
where
value
is a number or a parameter value. Use no
spaces before or after the equal (=) sign. If you type an
incorrect command or value, the display reads
??
.
Changes to the parameters are saved as they are
entered but typically do not take effect until you exit
setup mode.
For example, to set the motion band parameter to 5,
type the following:
MOTBAND
=
5D
<ENTER>
5.1.5
Soft Reset
The
RS
command will reset the
Tracer AV
without
losing configuration and calibration. It does reset
consecutive number.
Command
Function
DUMPALL
List all parameter values
VERSION
Tracer AV
software version
P
Write current displayed weight with units
identifier. See Section 6.2 on page 33 for
more information.
ZZ
Write current weight and annunciator
status. See Section 6.2 on page 33 for
more information.
S
Write one frame of stream format. See
Table 5-12 on page 30 for information
about the SX and EX commands.
Table 5-2. EDP Reporting Commands
Command
Description
Values
DEFCAL
Default Calibration
300lb, 500lb
GRADS
Graduations
1–100 000
ZTRKBND
Zero track band
OFF, 0.5D, 1D, 3D
ZRANGE
Zero range
1.9%, 100%
MOTBAND
Motion band
1D, 2D, 3D, 5D, 10D, 20D, OFF
OVRLOAD
Overload
FS+2%, FS+1D, FS+9D, FS
SMPRAT
Sample rate
15HZ, 30HZ, 60HZ, 7.5HZ
DIGFLTR1
DIGFLTR2
DIGFLTR3
Digital filtering
1, 2, 4, 8, 16, 32, 64
DFSENS
Digital filter cutout sensitivity
2OUT, 4OUT, 8OUT, 16OUT, 32OUT, 64OUT, 128OUT
DFTHRH
Digital filter cutout threshold
NONE, 2DD, 5DD, 10DD, 20DD, 50DD, 100DD, 200DD, 250DD
TAREFN
Tare function
BOTH, NOTARE, PBTARE, KEYED
Table 5-3. CONFIG EDP Commands