Ishida Uni-7 & Uni-5 Touch Screen Scale and Printer Setup Manual
Rev 4, B0674R / B0664J, March 2014
5
Uni-7+5_Setup_Manual
Figure 1.4.
Top, Red Bar Indicates Boot Up from USB Memory Stick
6. A warning message "Data Composition Is Different. Please Initialize the Memory" (0114-
0000) may be displayed if the current and new firmware versions differ greatly. If this
message appears press
OK
and skip to step 8.
7. Press the
MODE
key to enter the Main menu.
8. Enter
495344
and press the
PLU
key to access hidden menu steps.
9. Press the
ADJUST
menu button.
10. Scroll down and select
DOWNLOAD
(page 2/3).
11. At the DOWNLOAD (MAIN) screen press the
MAIN (ALL CLR)
button and press
EXECUTE
.
See Figure 1.5.
Figure 1.5.
Select and Execute
MAIN (ALL CLEAR)
12. A warning message "Data Composition Is Different. Please Initialize the Memory" (0114-
0000) may be displayed if the current and new firmware versions differ greatly. If this
message appears press
EXEC
to continue or
CANCEL
to stop and backup the scale data.
13. Press
EXEC
to begin clearing the existing firmware files from Flash ROM memory.
14. After the Flash ROM is cleared, the display will return to the DOWNLOAD (MAIN) screen.
15. Press the
USB>MAIN (PRG+IMG)
button.
See Figure 1.6.
16. Press the firmware version to be installed. It will be highlighted in yellow.
See Figure 1.6.