© Rice Lake Weighing Systems
●
All Rights Reserved
27
6.
0
Specification Setting
s
Span Switch must be enabled to use this function.
Enter
Z mode
before setting.
Press
to return to Z mode without saving.
6.
1
Customer Specification Settings
Operation
Function
Press and hold
and enter
,
,
.
Specification options will display.
Press
or
Increase or decrease Specification count.
Enter SPEC #, press
Enter desired Specification number.
Press
or
Moves cursor right or left.
Enter specification option, press
Enter option according to table, press
to move to next Specification.
Press
Store the updated information and return to
Z mode
.
Table 6-1. Specification Entry
SPEC Option
Description
00
Auto power saving when no weight change & no key press
0
Inhibit
1
3 minutes
2
10 minutes
3
30 minutes
4
1 hour
5
3 hours
01
Power saving mode
0
Back Light off
1
Power off
02
Negative Counting
0
No
1
Yes
03
Extent of insufficient samples
0
0.1%
1
0.2%
2
0.0%
04
Set new item during registration mode
0
Yes
1
No
05
Date order
0
Month/Day/Year
1
Day/Month/Year
2
Year/Month/Day
Table 6-1. Customer Specification Settings
Note
Specification Settings