7.9 Print Format Commands
7.10 Weigh Mode Commands
These commands function in the weigh mode. Non weight related commands work in setup mode.
Command
Description
Values
GFMT
GFMT.PORT
Gross demand print format string
For the .PORT commands, specify the port name as RS232-1, USB, NONE
Example: To send the Gross format out RS-232, send:
GFMT.PORT=RS232-1
for information about demand print format strings
NFMT
NFMT.PORT
Net demand print format string
ACCFMT
ACC.PORT
Accumulator print format string
Table 7-9. Print Format Commands
Command
Description
Values
P
Returns what the indicator is currently displaying
--
ZZ
Returns what the indicator is currently displaying;
as well as an additional number representing the
currently displayed annunciators
See
CONSNUM
Returns current consecutive number value
0–999999,
0
(default)
UID
Sets or returns the unit ID
Up to 8 alphanumeric characters,
1
(default)
SD
Sets or returns the current system date **
MMDDYY
,
DDMMYY, YYMMDD,
or
YYDDMM.
Enter six-digit date using the
year-month-day order specified for the DATEFMT parameter, using only the last two
digits of the year; The current system date is returned by only sending
SD
ST
Sets or returns the current system time **
HHMM
(enter using 24-hour format)
The current system time is returned by only sending
ST
STS
Sets or returns the current system time with
seconds **
HHMMSS
(enter using 24-hour format)
The current system time is returned by only sending
STS
RS
Resets system
Soft reset; Used to perform a power up reset of the indicator without resetting the
configuration to the factory defaults
SX
Starts all serial data streams
--
EX
Stops all serial data streams
--
SX#
p
Starts serial data stream for port
p
OK
or
??
An EX command sent while in setup mode does not take effect until the indicator is
returned to weigh mode
EX#
p
Stops serial data stream for port
p
SF#
n
Returns a single stream frame from scale
n
using
the standard Rice Lake format.
--
XA#
n
Returns the accumulator value in displayed units
nnnnnnnnnn UU
XAP#
n
Returns the accumulator value in primary units
XAS#
n
Returns the accumulator value in secondary units
XG#
n
Returns the gross weight in displayed units
nnnnnnnnnn UU
XGP#
n
Returns the gross weight in primary units
XGS#
n
Returns the gross weight in secondary units
XN#
n
Returns the net weight in displayed units
nnnnnnnnnn UU
XNP#
n
Returns the net weight in primary units
XNS#
n
Returns the net weight in secondary units
XT#
n
Returns the tare weight in displayed units
nnnnnnnnnn UU
XTP#
n
Returns the tare weight in primary units
XTS#
n
Returns the tare weight in secondary units
For commands ending with
#n
, n is the scale number (1); For commands ending with
#p
, p is the port number (1)
** Date/time functions only available with RTC option