Page 18
13. Remove the nozzle cover as shown on page 10,
II. Maintenance, B. Removing Nozzle Cover
14. Remove the screw and washer holding the motor cord in place (Fig. A.)
14. RSL2/RSL3/RSL4: Remove the crimp nuts holding the motor cord wires by squeezing them with
pliers as shown in Fig. B or cut the wires. Discard the old crimp nuts and the
power cord/motor cord assembly.
RSL5/RSL5C:
Remove the black, white, and red leads from the PC board (Fig. C) by squeezing
the connectors with needle nosed pliers. Remove the crimp nut from the green
wire by squeezing it with pliers as shown in Fig. B or cut the wire.
Discard the old crimp nut and power cord/motor cord assembly.
15. Rewire the motor cord using the appropriate wire diagram for the model located on pages 33-36.
16. Position the motor cord as shown in Fig. D and replace the washer and screw.
17. Reattach the nozzle cover.
Fig. A
Fig. B
Fig. C
Fig. D
II. Maintenance
F. Replacing the Power Cord (RSL2, RSL3, RSL3C, RSL4, RSL5, RSL5C cont.)