Connect the photocell transmitter to A+ TEST/A- and set DIP 7 to ON.
The monitoring consists of a functional test of the photocell run before every movement.
The gate movement is therefore permitted only if the photocells have passed the functional 
test.

CAUTION:

  MONITORING OF THE PHOTOCELLS INPUTS (PHOTO 1/PHOTO 2) CAN BE 

ACTIVATED WITH DIP 7 ON OR DEACTIVATED WITH DIP 7 OFF.

WARNING:  If the AUTOTEST feature is enabled and only one photocell is connected, 

a jumper must be made between the PHOT 1 and PHOT 2 terminals. If 
the jumper is not made, the AUTOTEST fails and the gate will not move.

PHOTOCELL AUTOTEST ALARM (DIP 7 ON)

If the photocell fails the monitoring test, an alarm is displayed by the blinker lighting up 
and gate movement is not allowed. Normal operation can be restored only by repairing the 
photocell and pressing one of the controls.

EDGES (SAFETY STRIPS) (COM A+/EDGE 1, COM A+/EDGE 2)

If engaged when closing, EDGE 1 reverses the motion in opening. If edge remains engaged, 
it doesn’t permit the closing.
If engaged during opening, EDGE 2 reverses the motion in closing. If edge remains engaged, 
it doesn’t permit the opening.
If edges are not used, jump the terminals COM A+/EDGE1/EDGE2.

EDGE ALARM

Flasher and buzzer are activated with 2 tones every 5 seconds for one minute.

STOP BUTTON (COM A+/STOP)
The STOP button stops the gate during any operation.

If held when the gate is fully open (or partially when using the pedestrian control) automatic 
closing is temporarily deactivated (if activated by the TCA trimmer and LED DL11 on). It is 
therefore necessary to use a new command to make it close.
The automatic closing function is reactivated on the next cycle (if activated by the TCA 
trimmer and LED DL11 ON).

FUNCTIONING IN HOLD-TO-RUN MODE WHEN THE SAFETY DEVICES ARE FAILING

If one of the safety edges fails or remains engaged for more than 5 seconds, or if one of the  
photocells fails or remain engaded for more than 60 seconds, the OPEN, CLOSE, START and 
PED. commands will work only in hold-to-run mode.
The signal that this mode has been activated is given by the blinking of the programming 
led DL1.
The radio commands and the automatic closing will be excluded, since their use in this mode 
is not allowed by the norms.
Once the failing safety device is repaired, in automatic after 1 second, all standard commands 
functioning again so radio commands and the automatic closing will be enabled again.

Note 1: 

 during this functioning in hold-to-run mode, in case of damage to the safety strips 
(or photocells) the photocells (or safety strips) still work by interrupting the operation 
in progress.

Note 2: 

 the stop command is not to be considered a safety command that can be bypassed 
in this mode. Therefore, when pressed or damaged, it will not allow any movement 
of the gate.

The hold-to-run mode is only an emergency operation which must be activated for a 
very short period and with the complete installation at sight so to have a secure and 
safe control of the system. As soon as possible however, the failing safety devices 
must be repaired and activated.

VISUAL AND SOUND ALARMS

BLINKER

Connect the flashing light to the blinker output, use flashing lights ACG7059 and bulbs of 
40W maximum.

PRE-BLINKING

DIP 5 - OFF => motor and blinker start simultaneously.
DIP 5 - ON => blinker starts 3 seconds before the motor.

BUZZER 

It has the task to signal the intervention of the security, the anomalies and the memorization 
and cancellation of the radio codes.

SIGNAL - 24Vdc GATE OPEN WARNING LIGHT (COM A+/SIGNAL-)

Signals when the gate is open, partially open or not closed completely. It turns off only when 
the gate is completely closed.
During opening, it flashes slowly.

When the gate is stationary or opened, it is permanently on.
During closing, it flashes quickly

N.B.:  Max 3 W. If warning lights are in excess, the control panel processes will be 

endangered with possible stop of all operations.

OPERATION AFTER BLACK-OUT

At the time of the blackout, gate status is saved in the memory.
When mains voltage is restored:

If the gate is located on the

 opening or closing limit switch, operating the control will close 

or open the gate with the saved data.

If the gate is in intermediate position

, operating the control will open the gate slowly until 

it reaches the opening limit switch. After completing this first movement, the operator will 
resume work at the set speed.

TECHNICAL SPECIFICATIONS

- Humidity 

 < 95% without condensation

- Power voltage 

 230V~ ±10% (120V/60Hz upon 
request)  

- Frequency 

50/60Hz

- Maximum board absorption 

30mA

- Interruptions in electricity supply 

100ms

- Maximum load of open gate output 

 3 W (equal to 1 3W bulb or to 5 LEDs 
connected in series through a resistor 
of from 2.2 Kohm)

- Blinking unit maximum output load 

 40W with resistive load

- Current available for photocells and accessories  400mA 24Vdc
- Current available on radio connector 

200mA 24Vdc

-  ALL THE PUSH BUTTONS, INPUTS AND COMMANDS CONNECTED TO THE CONTROL 

BOARD MUST BE CLEAN CONTACT.

TECHNICAL RADIO SPECIFICATIONS (Only L1-CRX)

- Reception frequency  

433,92MHz

- Impedance  

52 

Ω

- Sensitivity  

>2.24µV

- Excitation time  

300ms

- De-excitation time  

300ms

- Codes in store  

N° 1000 total

-  All the inputs must be used as clean contacts because the power supply is generated 

internally (safe voltage) in the card and it is set in a way to guarantee the use of the double 
insulation and reinforced in relation to parts with hazardous voltage.    

-  Any external circuits connected to the outputs of the control board, must be carried out to 

make sure the double or reinforced insulation is used in relation to parts with hazardous 
voltage.

-  All the inputs are run by a programmed integrated circuit  which carries out a self-check at 

the beginning of each operation. 

MAINTENANCE CHECK

N.B.:  During this check the safety functions Edges, Photocells and Stop button are 

NOT active.

1 - Set DIP 1 to ON => LED DL1 starts to flash.
2 -  Press and hold the PROG button (the command is hold-to-run, open-stop-close-stop-

open-etc ...) => The gate starts at high speed and then slow down until the limit switch 
is reached.

3 -  At the end, put DIP 1 back to the OFF position. The DL1 LED turn off signaling the exit 

from the check.

If the motor does not work during this check, check the connections and its capacitor.
If the motor is working properly, check the safety devices.

TROUBLE SHOOTING

After having carried out all connections, by carefully following the layout and having 
positioned the gate in intermediate position, check the correct ignition of red LEDS DL6, 
DL7, DL8, DL9 and DL10.
In case of no ignition of the LEDS, always with gate in intermediate position, check the 
following and replace any faulty components.
DL6 

OFF 

Stop button malfunction (if Stop is not connected, perform 

the jump between COM A+ and STOP).
DL7 or DL8 

OFF 

Faulty photocells (In case the edge is not connected, carry 

out jumper between COM A+ and PHOTO 1/PHOTO 2)

G

B

Summary of Contents for SUPER 3600

Page 1: ...024 Il corretto funzionamento dell operatore garantito solo se viene gestito da un quadro di comando RIB Le bon fonctionnement de l op rateur n est garanti que s il est g r par un panneau de contr le...

Page 2: ...nni provocati dalla mancata osservanza nell installazione delle norme di sicurezza e delle leggi attualmente in vigore ATTENTION POUR LA SECURITE DES PERSONNES IL EST IMPORTANT DE SUIVRE TOUTES LES IN...

Page 3: ...sed by the non observance during the installation of the safety standards and of the laws in force at present ACHTUNG F R DIE SICHERHEIT DER PERSONEN IST ES WICHTIG DASS ALLE ANWEISUNGEN GENAU AUSGEF...

Page 4: ...quisto di una nuova apparecchiatura di tipo equivalente Presso i distributori di prodotti elettronici con superficie di vendita di almeno 400 m2 inoltre possibile consegnare gratuitamente senza obblig...

Page 5: ...icace chiusura Il motore protetto da una sonda termica che in caso di utilizzo prolungato interrompe momentaneamente il movimento Misure in mm 1 CARATTERISTICHE TECNICHE SUPER 3600 Peso max cancello k...

Page 6: ...RA Persone esperte fuori da area pubblica Persone esperte area pubblica Persone non esperte mantenuto A B non possibile impulsivo in vista es pulsante C o E C o E C e D o E impulsivo non in vista es t...

Page 7: ...zionare a vista i due finecorsa F agendo sui pomoli P Dopo aver verificato il corretto funzionamento elettrico dei due microswitches si perfeziona la loro posizione fino ad ottenere l arresto in apert...

Page 8: ...2 FOTOCELLULA 2 COSTA 1 24Vdc 0 4A 15 24Vdc 0 4A 15 A TEST A AUTOTEST FOTOCELLULE ANTENNA 433 MHz SCHERMATURA CAVO D ANTENNA 700 W MAX CHIUDE APRE COMUNE ALIMENTAZIONE 230Vac 50 Hz CONDENSATORE COLLE...

Page 9: ...A Comune dei contatti Positivo 24 Vdc LIMIT SWITCH Contatti finecorsa che fermano il motore J8 PROBE NON DISPONIBILE J9 ENCODER NON DISPONIBILE J10 Terminazione RS485 di J11 J11 APP Connettore scheda...

Page 10: ...zioni di sicurezza Costa Fotocellule e Pulsante di stop sono attive ed il loro livello di prestazione pl b in accordo a EN13849 1 il loro intervento ferma la programmazione il led DL1 da lampeggiante...

Page 11: ...rocedura G PROGRAMMAZIONE CODICI RADIO PER REL R AUX MAX 1000 CODICI con modulo radio ACG8069 La gestione tramite telecomando attivabile solo con App RIB GATE R AUX funziona normalmente come luce di c...

Page 12: ...o quindi necessario dare un nuovo comando per farlo richiudere Al ciclo successivo la funzione chiusura automatica viene riattivata se abilitata tramite trimmer TCA e led DL11 acceso FUNZIONAMENTO AD...

Page 13: ...re pi facilmente la causa del guasto TABELLA RIASSUNTIVA ALLARMI VISIVI E SONORI SEGNALAZIONI IN FASE DI PROGRAMMAZIONE EVENTO STATO BUZZER STATO LAMPEGGIATORE STATO LED DL1 Dip 1 ON modo uomo present...

Page 14: ...erificare i collegamenti tra quadro elettronico e fotocellule Il cancello non apre e non chiude azionando i vari pulsanti START RADIO OPEN e CLOSE Contatto costa guasto Contatto fotocellule guasto con...

Page 15: ...ori prestazioni degli apparati sopracitati bisogna installare un antenna accordata sulla frequenza del radio ricevitore installato N B Fare molta attenzione che il filo centrale del cavo non vada a co...

Page 16: ...IVE DELLA COSTA VERTIGO Wi Fi 8 cod ACG8042 VERTIGO Wi Fi 10 cod ACG8043 COSTA SENZA FILI cod ACG3016 TRASMETTITORE RADIO RED per costa meccanica o elettrica da alimentare con 3 batterie stilo tipo AA...

Page 17: ...serrure lectrique pour une fermeture efficace Le moteur est prot g par une sonde thermique qui interrompt momentan ment le mouvement en cas de non utilisation prolong e Mesures en mm 1 CARACTERISTIQU...

Page 18: ...DE COMMANDE USAGE DE LA FERMETURE Personne expertes zone sans publique Personne expertes zone avec publique Personnes non expertes homme presente A B Pas possible impulsion en vue ex bouton C ou E C...

Page 19: ...came H en ouverture et en fermeture positionner vue les deux fins de course F en agissant sur les pommeaux P Apr s avoir contr l le fonctionnement lectrique correct des deux microinterrupteurs parfai...

Page 20: ...R 2 2K 1 4W COMMUN COMMUN COMMUN COMMUN CORDON 2 PHOTOCELLULES 2 CORDON 1 A TEST A AUTOTEST PHOTOCELULES ANTENNE 433 MHz ENVELOPPE ANTENNE 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX FERMETURE OUVERTURE CO...

Page 21: ...lules 2 NF EDGE 1 Contact barres palpeuse 1 NF EDGE 2 Contact barres palpeuse 2 NF J7 COM A Commun des contacts Positif 24 Vdc LIMIT SWITCH Contact fin de course qui arr te la fermeture du moteur J8 P...

Page 22: ...ART Commande impulsif vert CLOSE Commande fermeture vert OPEN Commande ouverture vert PROBE PAS DISPONIBLE C PROGRAMMATION DE LA DUR E N B Lors de la programmation les fonctions de s curit Coast Photo...

Page 23: ...ne s obtient que lorsque le portail est stationnaire 1 Positionner le DIP 1 sur ON et ensuite le DIP 3 sur ON 2 La LED DL12 clignote vert 6 fois indiquant la saturation de la m moire 1000 codes pr se...

Page 24: ...lignotant et le buzzer sont activ s avec 2 tons toutes les 5 secondes pendant une minute BOUTON D ARR T COM A STOP Fonction de s curit PL b selon EN13849 1 Pendant le mouvement le bouton d arr t effec...

Page 25: ...circuits externes connect s aux sorties de la centrale doivent tre ex cut s pour garantir l isolation double ou renforc e par rapport aux parties tension dangereuse Toutes les entr es sont g r es par...

Page 26: ...pi ton et R AUX 2 Tonalit s teint Effectue 2 clignotements verts SIGNALISATIONS PENDANT LE FONCTIONNEMENT V NEMENT TAT BUZZER TAT CLIGNOTEUR TAT LED ET SORTIE SIGNAL Bouton d arr t enfonc teint teint...

Page 27: ...ia Bluetooth 4 2 APP8064 Module Wi Fi pour Carte APP pour g rer le tableau de contr le via un r seau Wi Fi local WLAN APP8066 Module RJ45 pour Carte APP pour g rer le tableau de contr le via un r seau...

Page 28: ...e ACG8047 PAIRE DE POTEAUX pour NOVA code ACG8039 DISPOSITIFS Wi Fi MASTER Wi Fi FICHE DE GESTION SYST ME SANS FILS embrochable 12 30V ac dc code ACG6094 avec bornes visser 12 30V ac dc code ACG6099 N...

Page 29: ...D Key selector E Tuned aerial F Flashing lamp H Galvanized column for P E cells I Photo electric cells internal L Safety strip fixed to column M Mecanichal or electrical safety strip with RED transmit...

Page 30: ...to EN 12453 standard COMMAND TYPE USE OF THE SHUTTER Skilled persons out of public area Skilled persons public area Not skilled persons Hold to run operation A B Not possible Impulsive in sight e g pu...

Page 31: ...he two limit switches F by turning knobs P and judging by sight After checking for correct operation of the two microswitches precisely adjust their positions so that the gate will stop in the desired...

Page 32: ...R 2 2K 1 4W COMMON COMMON COMMON COMMON EDGE 2 PHOTOCELL 2 EDGE 1 A TEST A PHOTOCELLS AUTO TEST ANTENNA 433 MHz ANTENNA BRAIDING 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX CLOSE OPEN COMMON POWER SUPPLY 2...

Page 33: ...ls contact 2 NC EDGE 1 Edge 1 contact NC EDGE 2 Edge 2 contact NC J7 COM A Common contacts Positive 24 Vdc LIMIT SWITCH Limit switches that cuts off the motor J8 PROBE IS NOT AVAILABLE J9 ENCODER IS N...

Page 34: ...umpers between COM A STOP PHOT 1 PHOT 2 EDGE 1 EDGE 2 before proceeding with programming N B In this case the safety Edge Photocells and Stop button will be ignored N B The start slow down point is au...

Page 35: ...flashes of LED DL12 and two tones of the buzzer 3 LED DL12 blinks orange again for 10 seconds and you can add new codes as shown above 4 Re Set DIP 1 2 3 to OFF 5 End of procedure RADIO CODES MEMORY...

Page 36: ...ZZER It has the task to signal the intervention of the security the anomalies and the memorization and cancellation of the radio codes SIGNAL 24Vdc GATE OPEN WARNING LIGHT COM A SIGNAL Signals when th...

Page 37: ...econds Dip 1 2 3 transmitter code programming for R AUX relay Off Off Flashes orange for 10 seconds Correct transmitter codes programming for full opening and R AUX relay 1 Tone Off Turns green once C...

Page 38: ...ons between the control panel and the photocells The gate does not open or close by activating the various START RADIO OPEN and CLOSE buttons Faulty safety edge contact Faulty photocells contact with...

Page 39: ...the local network LAN SPARK In order to make the systems mentioned above give the best performances you need to install an antenna tuned on the frequency of the radio receiver installed N B Pay attent...

Page 40: ...SS PHOTOCELLS SUBSTITUTING THE SAFETY STRIP8 VERTIGO Wi Fi 8 code ACG8042 VERTIGO Wi Fi 10 code ACG8043 SAFETY STRIP WITHOUT WIRES code ACG3016 RED RADIO TRANSMITTER for mechanical and electrical safe...

Page 41: ...riegelung kein elektrisches Sicherheitsschloss Der Motor wird durch eine thermische Sonde gesch tzt die im Fall eines langen Einsatzes momentan die Bewegung unterbricht Abmessungen in mm 1 TECHNISCHE...

Page 42: ...ntlichen Bereichs Erfahrene Personen ffentlicher Bereich Nicht fachkundige Personen Gedr ckt halten A B nicht m glich Impulsiv in Sicht z B Wandtaster C oder E C oder E C und D oder E impulsiv au er S...

Page 43: ...schalter F durch Bet tigung der Kn pfe P auf Sicht zu positionieren Nach berpr fung der beiden Mikroschalter auf deren korrekte Funktionsweise Elektrik ist ihre Position genau einzustellen bis der Sto...

Page 44: ...NGSKONTAKT GEMEINSAMER ERDUNGSKONTAKT GEMEINSAMER GEMEINSAMER KONTAKTLEISTE 2 FOTOZELLE 2 KONTAKTLEISTE 1 A TEST A AUTOTEST FOTOZELLEN ANTENNE 433 MHz ANTENNE ZOPFFLECHTEN 24Vdc 0 4A 15 24Vdc 0 4A 15...

Page 45: ...takt 1 NS PHOT 2 Fotozellen Kontakt 2 NS EDGE 1 Ripppen Kontakt 1 NS EDGE 2 Ripppen Kontakt 2 NS J7 COM A Gemeinsame erdungskontakte Positive 24 Vdc LIMIT SWITCH Steckverbinder f r elektrische oder ma...

Page 46: ...VERF GBAR POINT C ZEITPROGRAMMIERUNG N B W hrend der Programmierung sind die Sicherheitsfunktionen Leerlauf Fotozellen und Stopptaste aktiv und ihr Leistungsniveau ist gem EN13849 1 b Ihr Eingriff st...

Page 47: ...1 und DIP 3 auf OFF stellen 4 Ende des Vorgangs H PROGRAMMIERUNG FUNKCODES F R R AUX RELAIS 1000 CODES MAX MIT RADIO MODUL ACG8069 Die Fernsteuerungsverwaltung kann nur mit der RIB GATE App aktiviert...

Page 48: ...r TCA aktiviert wurde und die LED DL11 leuchtet Es muss daher ein erneuter Schlie befehl gegeben werden Beim anschlie enden Bewegungszyklus wird die automatische Schlie funktion wieder aktiviert wenn...

Page 49: ...Spannung garantiert werden kann Alle Eing nge werden von einem programmierten integrierten Schaltkreis der bei jedem Start eines Laufes eine Selbstkontrolle vornimmt verwaltet WARTUNGS BERPR FUNG N B...

Page 50: ...fussg nger ffnung R AUX relais 2 T ne Abgeschaltet Blinkt 2 mal gr n SIGNALISIERUNGEN W HREND DES BETRIEBS EREIGNIS STATUS BUZZER STATUS BLINKLEUCHTE LEDZUSTAND UND AUSGANGSSIGNAL Stopptaste eingedr...

Page 51: ...uerungen hinzuzuf gen APP8064 WLAN Modul f r APP Karte Verwalten des Steuerung ber das lokale Wi Fi Netzwerk WLAN APP8066 RJ45 Modul f r APP Karte Verwalten der Steuerung ber das lokale Netzwerk LAN S...

Page 52: ...ULEN f r NOVA Kode ACG8039 Wi Fi VORRICHTUNGEN MASTER Wi Fi KARTE F R DEN BETRIEB DES SYSTEMS OHNE KABEL mit Verbinder 12 30V ac dc Kode ACG6094 mit Endblockierung 12 30V ac dc Kode ACG6099 NOVA Wi Fi...

Page 53: ...radura el ctrica para un cierre eficaz El motor est protegido por una sonda t rmica que en caso de uso prolongado interrumpe moment neamente el movimiento Medidas en mm 1 CARACTER STICAS T CNICAS SUPE...

Page 54: ...xpertas fuera de un rea p blica Personas expertas rea p blica Personas no expertas mantenido A B non posivel impulsivo a la vista por ejemplo bot n C o E C o E C e D o E impulsivo no a la vista p e ma...

Page 55: ...ovimiento de la camme H ya sea en abertura que en cierre posicionar en vista los dos finales de carrera F operando con los p mulos P Despu s de haber verificado el correcto funcionamiento el ctrico de...

Page 56: ...LED R 2 2K 1 4W COM N COM N COM N COM N BANDA 2 FOTOC LULA 2 BANDA 1 A TEST A AUTOPRUEBA DE FOTOC LULAS ANTENA 433 MHz ARMADURA ANTENA 24Vdc 0 4A 15 24Vdc 0 4A 15 700 W MAX CIERRE ABRE COM N ALIMENTAC...

Page 57: ...as 1 NC PHOT 2 Contacto de las fotoc lulas 2 NC EDGE 1 Contacto banda de seguridad 1 NC EDGE 2 Contacto banda de seguridad 2 NC J7 COM A Com n de los contactos Positivo 24 Vdc LIMIT SWITCH Contactos d...

Page 58: ...pertura NA verde PROBE NO DISPONIBLE C PROGRAMACI N DE LOS TIEMPOS N B Durante la programaci n las funciones de bandas de seguridad fotoc lulas y Stop est n activas y su nivel de rendimiento es pl b s...

Page 59: ...ON 2 El led verde DL10 parpadea 6 veces indicando la condici n de memoria saturada 1000 c digos presentes Sucesivamente el led DL12 permanece activo por 10 segundos permitiendo una posible cancelaci n...

Page 60: ...minuto PULSADOR DE STOP COM A STOP Durante cualquier operaci n el pulsador de STOP ejecuta la detenci n de la cancela Si se presiona con la cancela totalmente abierta o parcialmente utilizando el mand...

Page 61: ...s averiadas En caso que las fotoc lulas no estan conectadas realice el puente entre COM A y PHOTO 1 PHOTO 2 DL9 o DL10 apagado Bandas de seguridad averiados En caso que las bandas de seguridad no esta...

Page 62: ...000 c digos memorizados Apagado Apagado Realiza 6 parpadeos verdes Anulaci n c digos radio de apertura total peatonal y R AUX 2 Tonos Apagado Realiza 2 parpadeos verdes SE ALIZACIONES DURANTE EL FUNCI...

Page 63: ...uetooth 4 2 APP8064 M dulo wi fi para Tarjeta APP para administrar el panel de control a trav s de una red Wi Fi local WLAN APP8066 M dulo RJ45 para Tarjeta APP para administrar el panel de control a...

Page 64: ...es Conforme a la norma EN13849 1 2007 Unido a un cuadro electr nico RIB es un dispositivo de protecci n de Clase 2 c d ACG6202 E S SPARK Para obtener las mejores prestaciones de los citados aparatos e...

Page 65: ...2 Fotozellen FIT SLIM FIT SYNCRO mit Selbstkontrolle 2 fotoc lulas FIT SLIM FIT SYNCRO con autotest 2 fotocellule F97P F97I con autotest 2 photocellules F97P F97I avec autotest 2 photocells F97P F97I...

Page 66: ...UTOTEST est activ e et qu une seule photocellule est connect e un cavalier doit tre cr entre les bornes PHOT 1 et PHOT 2 Si le cavalier n est pas ex cut l autotest choue et le portail ne bouge pas WAR...

Page 67: ...forzo Super CCA1215 Protezione ingranaggio SUPER CCU6207 Cuscinetto 6207 35x72x17 CCU6307 Cuscinetto 6307 35x80x21 CEL1433 Pressacavo CAL1437 Condensatore 50 F 470V CME1034 Albero traino Super CME1063...

Page 68: ...2006 42 CE angewendet wurden Die bereinstimmung mit den genannten harmonisierten Normen sieht die Vermutung der bereinstimmung mit den festgelegten grundlegenden Anforderungen der Richtlinie vor die u...

Reviews: