33
G
B
A - CONNEXIONS
POWER
230 VAC
CAPACITOR
MOTOR
JC
T1
T2
JC
JB
JA
J7
J3
J8
J5
J6
J4
J2
J1
F1
J13
J14
J17
J15
J12
J16
J11
PROG
J1
L1 - N
230 Vac 50/60Hz power supply (120Vac 60Hz upon request)
J2
Flashing light (max 40W )
U
Motor common connection
V-W
Motor phases and capacitor connections
J3
R-AUX
Auxiliary relay contact (NO) Max 700 W
SIGNAL
Gate open state (24 Vdc 3 W max)
COM A+
Common contacts / Positive 24 Vdc
J4
A+ COM
+ 24Vdc accessories power supply / Common contacts
A-
- 24Vdc accessories power supply
A+ TEST
+ 24Vdc photocells self-test power supply
J5
COM A+
Common contacts / Positive 24 Vdc
B.I.O.
Contact (NO) dedicated to a clock
PED.
Pedestrian opening contact (NO)
START
Single pulse contact (NO)
CLOSE
Closing impulse contact (NO)
OPEN
Opening impulse contact (NO)
J6
COM A+
Common contacts / Positive 24 Vdc
STOP
STOP impulse contact (NC)
PHOT 1
Photocells contact 1 (NC)
PHOT 2
Photocells contact 2 (NC)
EDGE 1
Edge 1 contact (NC)
EDGE 2
Edge 2 contact (NC)
J7
COM A+
Common contacts / Positive 24 Vdc
LIMIT SWITCH Limit switches that cuts off the motor
J8
PROBE
IS NOT AVAILABLE
J9
ENCODER
IS NOT AVAILABLE
J10
RS485 termination of J11
J11
APP+
Connector for APP+ card
J12
APP
Connector for APP card
J13
SERIAL COM /
SYNC
Connector for serial connection
J14
-
-
J15
RADIO
Connector for radio module ACG8069
J16
RADIO
Connector for radio receiver RIB, 24 Vdc supply
J17
433 MHz Radio antenna
PROG.
Programming button
TCA
Trimmer for automatic closing time adjustment (DISABLED
DEFAULT AND DL11 LED OFF)
LOW SP
IS NOT AVAILABLE
TORQUE
IS NOT AVAILABLE
F1
T5A
Fuse for motor protection
CARD R2
T1 - T2 T
POWER RELAYS FOR THE COMMAND OF THE MOTOR
JA
R-N
SINGLE PHASE POWER SUPPLY - NEUTRAL
CONTACTS FOR THE EARTH CONECTION
U-V-W
MOTOR CONNECTION
JB
L1-N
SINGLE PHASE POWER SUPPLY FOR THE L1 CONTROL PANEL
TO BE DONE BY THE MANUFACTURER
JC
X-Y-Z
CONNECTION TO THE POWER RELAYS, TO BE DONE BY
THE MANUFACTURER
IT IS COMPULSORY TO SET THE
DIP 13 OF THE CONTROL PANEL
IN THE ON POSITION.