ECHNICAL DATA
- Moisture
< 95% without condensation
- Power supply voltage
230V~ ±10% (on request
120V±10%)
- Frequency
50/60 H
- Max. power consumption of the board 60 mA
- Transient power mains drops
100mS
- Max. capacity of the warning light - gate open 3W (corresponding to
1 3W lamp or to 5
LEDS with 2,2
resistance inseries
- Max. load at blinker output
40W with resistive load
- Available current for photocells and accessories 0,4 A ±15% 24Vac
- Available current for the radio connector
200mA 12Vdc
- All the inputs must be used as clear contacts because the power
supply is generated inside (safe power) the control panel, and it has
been laid down in such a way to guarantee a double or strengthened
insulation in relation to the parts with dangerous power.
- Eventual external circuits connected to the outputs of the control
board or of the expander card must be carried out making sure that a
double or strengthened insulation is used in relation to parts with
dangerous power.
- All inputs are run by a programmed integrated circuit which does a self
check every time it starts operating.
E
XTRA FUNCTIONS WITH
EXPANDER
(ACG5470)
!! FEED THE EXPANDER CARD IN WHEN POWER IS NOT
SUPPLIED !!
LÉGENDE
TR => Adjustment trimmer for the courtesy light time
1-2 => 24Vac power supply for photocells, FOTOOSTA units etc….
3-4 => Traffic light 1 contact
5-6 => Traffic light 2 contact
7-8 => Courtesy light contact
9 => Photocell 2 contact (NC)
10 => Pedestrian opening command (NO)
11 => Contact for safety edge when gate opens (NC)
12 => Common
unit
EXPANDER
CARD LED SIGNALS
D2 photocell 2 contact signal
D3 Signal for pedestrian opening contact
D4 Signal for safety edge
D5 voltage available
N.B.: LED D2, LED D4 and LED D5 must always be turned on for a
correct functioning.
PEDESTRIAN OPENING BUTTON (10-12)
This command operates the partial opening of the gate and Its closing.
When the gate Is partly open, it is not possible to operate its total
opening using the pedestrian command.
It is first necessary to close the gate than to open it totally.
NB: From modification SW.07 on cards KS and KS Super,
operation of the gate is as follows:
during the opening stroke,
the pause or the pedestrian closure, it is possible to start the
opening from any control connected to the card KS or KS Super.
Through DIP 5 it is possible to choose the mode of function of the
pedestrian command.
If DIP5 is set on OFF position => It is a cyclic command. Every
command operates a change; e.g.
open-stop-close-stop-open etc.
If DIP5 is set on ON position => Commands the opening when gate is
closed. If another command is sent
during the opening of the gate it will
have no effects. Commands the closing
when the gate id opened. If another
command is sent during the closing of
the gate it will re-open the gate.
LEARNING PROCEDURE FOR THE PEDESTRIAN OPENING
When the gate is closed and the closing limit switch is engaged
1 -
First position the DIP2 on mode ON
(the LED DL5 blinks quickly)
and then DIP1 on mode ON
(The LED DL5 blinks slowly).
2 - Press the pedestrian button (10-12) => The sliding gate opens.
3 - Press the pedestrian button to stop the travel (thereby determining
the gate opening).
4 - Wait the time you want the gate to remain open (excluded by
DIP3
to the OFF postion
), then press the pedestrian button to start the
closing.
5 -
Position DIP1 and 2 to the OFF position after the closing limit
switch has been reached.
Safety devices are active during the programming and their intervention
stops it (the LED blinks no more but remains constantly turned on).
To repeat the programming, position DIP1 and 2 on mode OFF, close
the gate and repeat the procedure described above.
AUTOMATIC PEDESTRIAN CLOSING
Pause times before the automatic pedestrian closing of the gate are set
during the Time Programming procedure. The max. pause time is 5
minutes.
You can enable or disable the pause time using DIP3 (ON enabled).
SAFETY EDGE IN OPENING (11-12)
If the safety edge intervenes during the opening of the gate, it
commands the reversal of the movement. This reversal will continue
D5
D4
D3
D2
GG
BB
ACCESSORIES -
For the connections and the technical data of the optional equipments follow the relevant
handbooks.
Summary of Contents for K1400 Plus
Page 8: ...8 8 I I COLLEGAMENTI ELETTRICI centralina KS cod BC07050 ...
Page 18: ...18 18 F F BRANCHEMENTS ÉLECTRIQUES coffret electronique KS cod BC07050 ...
Page 28: ...28 28 G G B B ELECTRIC CONNECTIONS electric board KS code BC07050 ...
Page 38: ...38 38 D D ELEKTROANSCHLÖÜSSE elektronische steuerung KS code BC07050 ...
Page 48: ...48 48 E E S S CONEXIONES ELÉCTRICAS panel electronico KS cód BC07052 ...