WARNING!
The length of connection cables from the motors to the control panel unit must not exceed 15 m. The wire section of the motor power supply must be
1.5 mm
2
, whilst that of the accessories must be 0,75 mm
2
. As for the encorder it is very important to use a shielded wire with a section of 0,75 mm
2
(for example type ÖLFLEX-110 CH - Code ACG2133). It is compulsory to use shielded cable for the encoder in order to guarantee the correct
operation of the control board.
The screen of the ENCODER cable must be earth grounded at one end (not to the card GND), and at the
opposite end the screen must be free (conductor not connected).
To ensure the correct functioning of the installation it is advisable to wire encoder and motor with separate cables.