TROUBLESHOOTING
!
WARNING
Before attempting to service or
troubleshoot the generator, the owner
or service technician must fi rst read
the owner’s manual and understand
and follow all safety instructions.
Failure to follow all instructions may
result in conditions that can lead to
voiding of product warranty, serious
personal injury, property damage or
even death.
PROBLEM
POTENTIAL CAUSE
SOLUTION
Engine is running, but no
electrical output.
1.
Circuit breakers are tripped.
1.
Reset the circuit breakers and check for overload
condition
.
2
.
Faulty or defective power cord
2
.
Replace power cord.
3
.
Faulty or defective electrical
appliance
3
.
Try connecting a known good appliance to verify the
generator is producing electrical power.
4
.
If trying 1-
3
above does not
solve the problem, the cause
might be the generator has a
fault.
4
.
Take the generator to your nearest authorized
service dealer.
Engine will not start or
remain running while trying
to start.
1.
Fuel shutoff valve is in the
OFF
position.
1.
Move the fuel shutoff valve to the
ON
position
2.
Generator is out of gasoline.
2.
Add gasoline to the generator
3.
Fuel fl ow is obstructed.
3.
Inspect and clean fuel delivery passages.
4.
Unit is overchoked.
4.
Move the choke lever halfway between the
ON
and
OFF
positions
5.
Starting battery may have
insuffi cient charge
5.
On electric start models only. Check battery output
and charge battery as necessary.
6.
Dirty air fi lter
6.
Check and clean the air fi lter.
7.
Low oil level shutdown switch
is preventing the unit from
starting.
7.
Check oil level and add oil if necessary
8
.
Spark plug is faulty.
8
.
Remove and check the spark plug. Replace if faulty
9
.
Dirty/plugged spark arrestor
9
.
Check and clean the spark arrestor
1
0
. Stale fuel
1
0
. Drain fuel and replace with fresh fuel
1
1
. If trying 1-1
0
above does not
solve the problem, the cause
might be the generator has a
fault.
1
1
. Take the generator to your nearest authorized
service dealer.
EN