6
. Install the air cleaner cover by re-engaging the tabs
on the top of the air cleaner assembly and then
installing the release knob by turning clockwise.
Installation of Air Cleaner Cover
CAUTION:
Never run the engine without the air cleaner element. Rapid
engine wear will result from contaminants, such as dust and dirt,
being drawn through the carburetor, into the engine.
2. Move the fuel shutoff valve to the
ON
position.
Fuel Shutoff Valve in the
ON
Position
STARTING THE GENERATOR
Before starting the generator, read manuals
.
Before attempting to start the generator, verify the
following:
The engine is f
i
lled with engine oil
(see Checking
Engine Oil
.
The generator is situated in a proper location
(see
Location Selection
.
The generator is on a dry surface
(see Weather
and
Dry Surface
.
All loads are disconnected from the generator
(see
No Connected Loads
.
The generator is properly grounded
(see Grounding
the Generator
.
Manually Starting a Generator
NOTE: This procedure can also be used on an
electric start generator.
1. Make sure the circuit breakers are properly set
.
1
2
3
4
B
reakers
1 -
240/120V Main
Circuit Breaker
Operating
Position
2 -
240/120V Main
Circuit Breaker
Tripped Position
3 -
120V Circuit
Breaker
Operating
Position
4 -
120V Circuit
Breaker Tripped
Position