Specifications are based on the following conditions.
• Power source of specifications: 230 V
• 7: 7,000 Btu/h, 9: 9,000 Btu/h, 12: 12,000 Btu/h
• 2 indoor units should be connected.
• Heating: Indoor temperature of 70 °FDB (21.1 °CDB)/60 °FWB (15.6 °CWB), and outdoor
temperature of 47 °FDB (8.3 °CDB)/43 °FWB (6.1 °CWB).
• Pipe length: 24.6 ft (7.5 m), Height difference: 0 ft (0 m) [Outdoor unit—Indoor unit]
• The total ability of connected a indoor unit is up to 21,000 Btu from 14,000 Btu.
• Non-Ducted system combinations input are based on
RIWH
wall mount models. The input of
combinations including
RICH
cassette models may be a little higher.
• Ducted system combinations capacities are based on
RIDH
slim duct units excepting 7,000-
Btu
models. 7,000 Btu models are based on
RIWH
wall mount models.
Combination of indoor unit
Rated capacity for each
indoor unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1
Room 2
Total
Room 1
Room 2
Room 1
Room 2
Min.
Rated
Max.
Min.
Rated
Max.
7
7
14
9.20
9.20
10.35
10.35
6.80
18.40
20.70
0.52
1.50
1.97
7
9
16
8.93
11.48
9.58
12.32
6.80
20.40
21.90
0.52
1.77
1.92
7
12
19
8.11
13.89
8.99
15.41
6.80
22.00
24.40
0.52
1.87
2.10
9
9
18
11.00
11.00
12.20
12.20
6.80
22.00
24.40
0.52
1.87
2.10
9
12
21
9.43
12.57
10.46
13.94
6.80
22.00
24.40
0.52
1.88
2.10
Combination of indoor unit
Rated capacity for each
indoor unit (kBtu/h)
Maximum capacity for each
indoor unit (kBtu/h)
Total capacity
(kBtu/h)
Input power (kW)
Room 1
Room 2
Total
Room 1
Room 2
Room 1
Room 2
Min.
Rated
Max.
Min.
Rated
Max.
7
9
16
8.93
11.48
9.58
12.32
6.80
20.40
21.90
0.52
1.73
1.90
7
12
19
8.11
13.89
8.99
15.41
6.80
22.00
24.40
0.52
1.83
2.08
9
9
18
11.00
11.00
12.20
12.20
6.80
22.00
24.40
0.52
1.83
2.08
9
12
21
9.43
12.57
10.46
13.94
6.80
22.00
24.40
0.52
1.84
2.08
Summary of Contents for RICH07AVFJ
Page 8: ......
Page 20: ...12...
Page 45: ...37...
Page 46: ...38...
Page 58: ...50 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 59: ...51 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 60: ...52...
Page 61: ...53 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 68: ...60...
Page 69: ...61 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 70: ...62 MULTI TYPE 2 3 4 ROOMS TYPE Models RIWH18AVFJ and RIWH24AVFJ...
Page 71: ...63 MULTI TYPE 2 3 4 ROOMS TYPE 5 4 Floor type Models RIFH9AVFJ RIFH12AVFJ and RIFH15AVFJ...
Page 92: ...84 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 93: ...85 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 94: ...86 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 95: ...87 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 96: ...88 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 114: ...106 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 123: ...115 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 124: ...116 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 125: ...117 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 177: ...169 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 178: ...170 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 190: ...182 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 191: ...Part 2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE ROMH18AFXZJ...
Page 197: ...189 OUTDOOR UNIT ROMH18AFXZJ 4 Refrigerant circuit 4 1 Model ROMH18AFXZJ...
Page 198: ...190 OUTDOOR UNIT ROMH18AFXZJ 5 Wiring diagram 5 1 Model ROMH18AFXZJ...
Page 221: ...Part 3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE ROMH24AFXZJ...
Page 228: ...220 OUTDOOR UNIT ROMH24AFXZJ 4 Refrigerant circuit 4 1 Model ROMH24AFXZJ...
Page 229: ...221 OUTDOOR UNIT ROMH24AFXZJ 5 Wiring diagram 5 1 Model ROMH24AFXZJ...
Page 265: ...Part 4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE ROMH36AFXZJ...
Page 273: ...265 OUTDOOR UNIT ROMH36AFXZJ 5 Wiring diagram 5 1 Model ROMH36AFXZJ...