- 126 -
MULTI TYPE
2, 3, 4 R
O
OMS TYPE
z
Circuit diagram example
• When function setting is "Operation/Stop" mode
• When function setting is "Forced stop" mode
• Contact capacity: DC 24 V or more, 10 mA or more.
• *1: PCB of Communication kit is used for wall mounted
(
RIWH
7
AVFJ
,
RIWH
9
AVFJ
,
RIWH
12
AVFJ,
and
RIWH
15
AVFJ
) type.
• *2: Make the distance from the PCB to the connected unit
within 33 ft (10 m).
• Use non-polar relays and switches.
Indoor unit type
1-pin
3-pin
(Polarity)
(Polarity)
Compact cassette
-
+
Slim duct
-
+
Wall mounted
RIWH
7
AVFJ
,
RIWH
9
AVFJ
,
RIWH
12
AVFJ
,
RIWH15AVFJ RIWH
18
AVFJ
,
RIWH
24
AVFJ
-
+
Floor
RIFH9AVFJ
,
RIFH
12
AVFJ
,
RIFH
15
AVFJ
-
+
Indoor unit
control PCB
*1
Example: Switch
Locally purchased
Connected unit
1
3
Signal
Connector
33 ft. (10 m)*2
Operation
Stop
On
Off
Input signal
Indoor unit
Remote controller
On
On
On
Input signal
Indoor unit
Command
Remote control
operation invalidity
On
Off
Operation
Stop
Forced stop
Normal
Summary of Contents for RICH07AVFJ
Page 8: ......
Page 20: ...12...
Page 45: ...37...
Page 46: ...38...
Page 58: ...50 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 59: ...51 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 60: ...52...
Page 61: ...53 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 68: ...60...
Page 69: ...61 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 70: ...62 MULTI TYPE 2 3 4 ROOMS TYPE Models RIWH18AVFJ and RIWH24AVFJ...
Page 71: ...63 MULTI TYPE 2 3 4 ROOMS TYPE 5 4 Floor type Models RIFH9AVFJ RIFH12AVFJ and RIFH15AVFJ...
Page 92: ...84 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 93: ...85 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 94: ...86 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 95: ...87 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 96: ...88 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 114: ...106 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 123: ...115 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 124: ...116 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 125: ...117 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 177: ...169 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 178: ...170 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 190: ...182 MULTI TYPE 2 3 4 ROOMS TYPE...
Page 191: ...Part 2 OUTDOOR UNIT 2 ROOMS TYPE MULTI TYPE ROMH18AFXZJ...
Page 197: ...189 OUTDOOR UNIT ROMH18AFXZJ 4 Refrigerant circuit 4 1 Model ROMH18AFXZJ...
Page 198: ...190 OUTDOOR UNIT ROMH18AFXZJ 5 Wiring diagram 5 1 Model ROMH18AFXZJ...
Page 221: ...Part 3 OUTDOOR UNIT 3 ROOMS TYPE MULTI TYPE ROMH24AFXZJ...
Page 228: ...220 OUTDOOR UNIT ROMH24AFXZJ 4 Refrigerant circuit 4 1 Model ROMH24AFXZJ...
Page 229: ...221 OUTDOOR UNIT ROMH24AFXZJ 5 Wiring diagram 5 1 Model ROMH24AFXZJ...
Page 265: ...Part 4 OUTDOOR UNIT 4 ROOMS TYPE MULTI TYPE ROMH36AFXZJ...