background image

Effective: 01-15-20 

Replaces: 12-10-19 

P/N 241831 Rev 3

INSTALLATION 

AND OPERATION 

MANUAL

Models  

RPAGP75, RPAGP100, 

RPAGP102, RPAGP150, 

RPAGP152

IMPORTANT SAFETY INSTRUCTIONS. READ AND FOLLOW ALL 

INSTRUCTION. SAVE THESE INSTRUCTIONS.

NOTE:

 The instructions in this manual are for the use of qualified individuals specially trained and experienced 

in the installation and maintenance of this type of equipment and related system components. Installation and 

service personnel are required by some states to be licensed. Persons not qualified shall not attempt to install, 

service, or maintain this equipment.

This manual should be maintained in legible condition and kept adjacent to the sand filter or in a safe place for 

future use.

SWIMMING POOL  

PUMP 

CONTROLLED COPY approved for factory use on 4/16/2020.  RAYPAK PROPRIETARY AND CONFIDENTIAL INFORMATION .  Approval signatures on file in Engineering.

Summary of Contents for Raypak RPAGP100

Page 1: ...d experienced in the installation and maintenance of this type of equipment and related system components Installation and service personnel are required by some states to be licensed Persons not qual...

Page 2: ...ion to these Terms 3 2 IMPORTANT SAFETY INSTRUCTIONS 5 Entrapment Prevention 5 3 OVERVIEW 6 Constant Speed Pump Models 6 Dual Speed Pump Models 6 4 INSTALLATION 6 Pump 6 5 START UP 8 6 GENERAL MAINTEN...

Page 3: ...well as disinfectant feed ratios A AWARNING DO NOT increase pump size this will increase the flow rate through the system and exceed the maximum flow rate stated on the drain cover A AWARNING Before i...

Page 4: ...interrupter GFCI should always be installed at the power supply source of this unit Article 681 31 of the NEC requires that a GFCI be used if this pump is used with a storage pool Be sure to ground t...

Page 5: ...drains from the pump The system shall be constructed so that it shall not allow for separate or independent shutoff or isolation of each drain More than one pump can be connected to a single suction...

Page 6: ...pump is used with a storage pool Be sure to ground the motor before connecting it to an electrical AC power source Failure to ground the motor can cause serious or fatal electrical shock hazard DO NO...

Page 7: ...RPAGP100 0 75kW 1 0 Single RPAGP102 0 75kW Max 1 0 Dual RPAGP150 1 1kW 1 5 Single RPAGP152 1 1kW Max 1 5 Dual DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this...

Page 8: ...pressure from the system before proceeding 2 Unscrew the trap lid pre filter lid by turning counterclockwise 3 Remove the strainer basket and clean it Be sure all holes in the basket are unclogged th...

Page 9: ...tion or discharge line is partly closed Open or replace the valve Suction or discharge line is partly plugged Clear the obstruction Suction or discharge line is too small Re plumb use a larger pipe di...

Page 10: ...50F Kit Pump Impeller RPAGP150 152 018251F 6 7 018225F 018227F 5 Kit Transparent Cover AGP Kit Mechanical Seal 1 2 with O Ring Table C Replacement Parts 1 2 3 4 6 7 5 Figure 3 Pump with Motor Exploded...

Page 11: ...ak com warranty then the Applicable Warranty Period is one 1 year from the Effective Date for the PUMP and component parts LABOR AND SHIPPING COSTS This Limited Warranty does NOT cover any travel time...

Page 12: ...ES ON RAYPAK S BEHALF ANY IMPLIED WARRANTIES INCLUDING MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE SHALL NOT EXTEND BEYOND THE APPLICABLE WARRANTY PERIOD SPECIFIED IN THIS LIMITED WARRANTY RAY...

Reviews: