7
Model
Input power
(KW)
Power
(HP)
Speed
Voltage
Full Load
Current (A)
Connection
Size
RCAGP100
0.75
1.0
Single
115V/60Hz
9.5
1.5″
(32-38 mm)
RCAGP102
0.75 (Max)
1.0
Dual
9.5
RCAGP150
1.1
1.5
Single
10.5
RCAGP152
1.1 (Max)
1.5
Dual
10.5
Table A.
Specifications
11.07"
(281.1 mm)
10.24"
(260 mm)
14.31"
(263.6 mm)
10.23"
(259.9 mm)
22.95"
(
582.90
mm)
Figure 2.
Dimensions
• Connect the suction and discharge pipes to the outlet
and inlet of the swimming pool.
• Make sure that ground level drainage is adequate so
as to prevent flooding.
• DO NOT store or use gasoline or other flammable
vapors or liquids in the vicinity of this pump. DO NOT
store pool chemicals near the pump.
• DO NOT remove any safety alert labels such as
DANGER, WARNING, or CAUTION. Keep safety
labels in good condition and replace any missing or
damaged labels.
• Make sure that the pump and piping are accessible
for servicing.
NOTE:
The pump suction and discharge connections
have molded-in thread stops. DO NOT try to screw pipes
beyond these stops.
5. START-UP
A
WARNING:
NEVER run pump dry! Running the pump
dry may damage seals, causing leakage or flooding! Fill
the pump with water before starting the motor. It is an
above ground pool pump and cannot self-prime. Fill the
pump with water before starting.
•
Always STOP THE PUMP before and RELEASE ALL
PRESSURE from the pump and the piping system
before proceeding.
•
NEVER tighten or loosen screws while the pump is
operating.
•
Do not block pump suction.
A
WARNING:
Do not block pump suction! To do so with
body parts may cause severe or fatal injury. Children
using pool must ALWAYS have close adult supervision.
Pump Priming and Start-up
Priming
• Release all air from the filter and piping system (see
filter instructions in "General Maintenance" section).
• In a flooded suction system (water source higher than
pump) the pump will prime itself when the suction
and discharge valves are opened.
• If the pump is not in a flooded suction system,
unscrew and remove the trap cover, then fill the trap
and pump with water.
• Clean and inspect the O-Ring. Re-install it on the trap
cover.
• Replace the trap cover on the trap; turn clockwise to
tighten the cover.
• Turn the power “ON” at the house circuit breaker.
Optional - Set the pool time clock to the correct time.
• Start the pump by toggling its power switch to the
"ON" position. For the 2-speed models, the power
switch toggles between high-speed, "OFF", and low-
speed positions.
• Optional - Bleed out pool filter - Open the manual air
relief valve on the filter, manually bleed the air out
until a steady water stream is evident. Close the
manual relief valve.
NOTE:
Tighten the trap cover by hand only. Priming
time will depend on the vertical length of suction lift and
the horizontal length of the suction piping.
APPROVED
UNCONTROLLED DOCUMENT IF PRINTED