RFS RRH jumper with FullAXS compatible connector installation guide
Use the following instruction to properly install/attach the FullAXS compatible connector. Failure to follow
these procedures entirely may cause damage to the Fiber or Connector. For factory pre-installed assembly,
skip to step 4a:
Carefully feed compression nut over fiber jumper connector and slide onto jacketing. Do not twist or bend
the LC connector or fiber. Excessive force or bending may break the fiber or connector components.
Feed the fiber connector into the sleeve until the connector comes out. Caution: do not apply too
much force as doing so can cause damage to the fiber and gland spring fingers.
\
Wrap the rubber split grommet around the jacketing and
VERY CAREFULLY
push it
UNDER
the clamping fingers until
the grommet is flush with the finger ends (Caution: it will be necessary to gently lift the fingers)
Caution!
1
3
2
Flare End
Connector Clip position
Angle fiber position toward Clip
Angle