FEATURES

 

1.

 

The

 

RFAS8810

 

is

 

a

 

programmable,

 

eight

channel

 

test

 

subsystem,

 

with

 

a

 

frequency

 

range

 

of

 

0.8

 

to

 

3

 

GHz

 

and

 

an

 

attenuation

 

range

 

of

 

0

 

to

 

110

 

dB.

 

2.

 

The

 

unit

 

runs

 

on

 

the

 

Windows

 

operating

 

system,

 

and

 

is

 

controlled

 

through

 

an

 

RJ45

 

Ethernet

 

interface

 

by

 

TCP/IP

 

protocol.

 

In

 

order

 

to

 

control

 

the

 

attenuation

 

of

 

each

 

channel,

 

accessible

 

by

 

RS232

 

serial

 

communication,

 

users

 

can

 

write

 

PC

 

control

 

programs

 

in

 

VBScript,

 

under

 

the

 

RS232

 

serial

 

communication

 

protocol.

 

3.

 

The

 

programmable

 

test

 

subsystem

 

can

 

simplify

 

test

 

setups,

 

such

 

as

 

handover,

 

variable

 

handover,

 

and

 

fade

 

attenuator.

 

Its

 

most

 

common

 

use

 

is

 

in

 

wireless

 

communication

 

signal

 

tests,

 

in

 

the

 

standard

 

19

inch

 

rack

 

package,

 

with

 

high

 

accuracy

 

and

 

stability.

 

In

 

addition

 

to

 

adjusting

 

the

 

unit

 

remotely

 

through

 

LAN,

 

RS

232,

 

or

 

USB

 

interface,

 

you

 

can

 

also

 

easily

 

adjust

 

it

 

in

 

local

 

manual

 

mode.

 

With

 

a

 

large

 

LCD

 

display,

 

keyboard,

 

and

 

knob,

 

the

 

sub

system

 

also

 

has

 

the

 

capability

 

of

 

sending

 

and

 

receiving

 

RS

232

 

and/or

 

Ethernet

 

commands

 

that

 

you

 

can

 

format

 

to

 

meet

 

your

 

specific

 

command

 

requirements.

 

 

 

Summary of Contents for RFAS8810

Page 1: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 1 Model No RFAS8810 8 IN 8 OUT Programmable Attenuator Subsystem...

Page 2: ...s Setting 8 3 Remote Local Setting 8 4 Single channel Attenuation Setting 9 5 Multiple channel Attenuation Setting 11 6 All Channel Attenuation Setting 12 7 IP Address Change 13 REMOTE CONTROL 14 1 Po...

Page 3: ...mmunication users can write PC control programs in VBScript under the RS232 serial communication protocol 3 The programmable test subsystem can simplify test setups such as handover variable handover...

Page 4: ...Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 4 4 Panel view Front panel Back panel 5 Physical Dimensions units mm in...

Page 5: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 5 SIGNAL DIAGRAM...

Page 6: ...m 1 3 1 typical Attenuation Accuracy 0 5 dB 10 dB 1 0 dB 10 31 dB 1 5 dB 32 63 dB 2 5 dB 64 110 dB Insertion Loss 16 dB maximum RF Input Power 30 dBm average Switching Speed 2 us typical AC Supply 100...

Page 7: ...USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 7 LOCAL CONTROL 1 Power On When the power comes on the following boot screen displays Figure 1 Boot Screen After a few seconds you wi...

Page 8: ...nd notice that the field is now highlighted in blue Type 224 Use the ESC key to cancel mistakes After you finish press F1 to save the setting The remote local setting screen will open Figure 3 Remote...

Page 9: ...hannel indicated by an asterisk See Figure 6 Press ENTER to return the main screen and the color of active channel will change from black to blue There are two ways to set the attenuation value One wa...

Page 10: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 10 Figure 5 Channel setting Figure 6 Single Channel Setting...

Page 11: ...e knob to align the asterisk with an intended channel and then press the knob slightly to select the channel Pressing the knob twice will cause the symbol to disappear meaning no channel is selected I...

Page 12: ...vance to the channel setting screen To select all channels from the channel setting screen press F3 Figure 9 Return to the main screen and notice that all channels are displayed in blue Figure 9 indic...

Page 13: ...499 1302 www rflambda com Page 13 Figure 9 All Channel Setting 7 IP Address Change With the main screen in local mode you can verify the current IP address and change the IP address by pressing F3 Fig...

Page 14: ...972 499 1302 www rflambda com Page 14 REMOTE CONTROL 1 Port Configuration Software Installation Begin by installing the serial port server driver Open the NE 4110S folder and click neadm_setup_Ver2 1...

Page 15: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 15 Click the Next button The following window opens...

Page 16: ...LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 16 Click the Next button The following window opens Click Install to open the insta...

Page 17: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 17 After the installation is complete the following window opens Click Finish to finalize the installation 2 Port Configurat...

Page 18: ...x 972 499 1302 www rflambda com Page 18 To modify the IP address with the unit connected to the PC via parallel cable begin by opening the Configuration menu and selecting Broadcast Search The system...

Page 19: ...ouble click on the system whose IP address you want to modify NE 4110S in the illustrated example to open its IP Settings window In the Configuration window select the Network tab check the Modify che...

Page 20: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 20 To confirm your selections click OK...

Page 21: ...024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 21 Open Internet Explorer and enter the unit s IP address From the Main Menu open the Serial Settings folder adjust the parameters...

Page 22: ...972 499 1302 www rflambda com Page 22 From the Main Menu open the Operating Settings folder adjust the parameters as necessary click on Submit to confirm your selections and close IE 3 Operating Softw...

Page 23: ...860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 23 Read the text on the screen and click on Next to advance to the next screen Do not re...

Page 24: ...trol Interface Click on the icon 8in8outProgrammableSubsystem exe or choose Start All Programs 8in8out ProgrammableSubsystem exe Because of the test subsystem s access to the LAN the network computer...

Page 25: ...allas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 25 Clicking on Disconnect will disconnect the communication subsystem Click either or to toggle...

Page 26: ...e instructions Set single channel attenuation values In the text box next to each channel ANT1 ANT2 ANT3 etc enter the intended channel attenuation value and click Send to confirm your selection Each...

Page 27: ...767 5998 Fax 972 499 1302 www rflambda com Page 27 Multi channel Attenuation Setting Begin by selecting the channels you intend to set Do this by checking the box to the left of the channel label Then...

Page 28: ...A Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 28 Road through operational settings Click on Visible Port and select the interface to operate by checking the box next to the interface...

Page 29: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 29 To customize the name of a channel begin by clicking on Tools...

Page 30: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 30 The Frm_Tools window opens Click on Profile The Frm_Profile window opens Use the text box next to the channel label to mo...

Page 31: ...the name will automatically be saved To set an attenuation value for all eight channels simultaneously begin at the 8in8out Programmable Subsystem window Click on Tools As with the channel name custom...

Page 32: ...lephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 32 To set an initialized value for the attenuation open the Frm_Tools window as in the two previous procedures Choose a value from the Initi...

Page 33: ...phone 972 767 5998 Fax 972 499 1302 www rflambda com Page 33 Save and return to the main interface when in the Settings drop down list select a channel click on Iinitiallze later In addition to the se...

Page 34: ...ay Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 34 Click AutoScript run into the automation interface Set the appropriate parameters the first point of Ap...

Page 35: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 35 Point Pause pause point Quit to exit Other buttons Read All to read the current attenuation value of all channels About Sy...

Page 36: ...CUSTOM SCRIPT SETTINGS Run automation script From the primary window select Browse and then navigate to the location of the VBScript Begin the script by clicking on Run R Communication protocol can b...

Page 37: ...rkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 37 ACCESSORIES 1 110V 220V power cable 1pcs 2 CD driver control software user manual 1pcs 3 User manual...

Page 38: ...Get the output port connected to any input port It is used in a power Combiner system LO Lock keyboard of the system LU Unlock keyboard of the system RT Restart system Enter HX and command without spa...

Page 39: ...LF Set Switch The set switch command is used to set a switch to a specifi c port number Syntax SSx y CR LF x switch number y port number Example SS11 8 CR LF Sets switch 11 to port 8 System will retu...

Page 40: ...et the output port connected to any input port It is used in a power Combiner system Syntax ROx CR LF x input port Example RO 1 CR LF Get the output port connected to input 1 System will return RO1 1...

Reviews: