Open

 

Internet

 

Explorer,

 

and

 

enter

 

the

 

unit’s

 

IP

 

address.

 

 

 

 

From

 

the

 

Main

 

Menu,

 

open

 

the

 

Serial

 

Settings

 

folder,

 

adjust

 

the

 

parameters

 

as

 

necessary,

 

and

 

click

 

on

 

Submit

 

to

 

confirm

 

your

 

selections.

 

Summary of Contents for RFAS8810

Page 1: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 1 Model No RFAS8810 8 IN 8 OUT Programmable Attenuator Subsystem...

Page 2: ...s Setting 8 3 Remote Local Setting 8 4 Single channel Attenuation Setting 9 5 Multiple channel Attenuation Setting 11 6 All Channel Attenuation Setting 12 7 IP Address Change 13 REMOTE CONTROL 14 1 Po...

Page 3: ...mmunication users can write PC control programs in VBScript under the RS232 serial communication protocol 3 The programmable test subsystem can simplify test setups such as handover variable handover...

Page 4: ...Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 4 4 Panel view Front panel Back panel 5 Physical Dimensions units mm in...

Page 5: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 5 SIGNAL DIAGRAM...

Page 6: ...m 1 3 1 typical Attenuation Accuracy 0 5 dB 10 dB 1 0 dB 10 31 dB 1 5 dB 32 63 dB 2 5 dB 64 110 dB Insertion Loss 16 dB maximum RF Input Power 30 dBm average Switching Speed 2 us typical AC Supply 100...

Page 7: ...USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 7 LOCAL CONTROL 1 Power On When the power comes on the following boot screen displays Figure 1 Boot Screen After a few seconds you wi...

Page 8: ...nd notice that the field is now highlighted in blue Type 224 Use the ESC key to cancel mistakes After you finish press F1 to save the setting The remote local setting screen will open Figure 3 Remote...

Page 9: ...hannel indicated by an asterisk See Figure 6 Press ENTER to return the main screen and the color of active channel will change from black to blue There are two ways to set the attenuation value One wa...

Page 10: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 10 Figure 5 Channel setting Figure 6 Single Channel Setting...

Page 11: ...e knob to align the asterisk with an intended channel and then press the knob slightly to select the channel Pressing the knob twice will cause the symbol to disappear meaning no channel is selected I...

Page 12: ...vance to the channel setting screen To select all channels from the channel setting screen press F3 Figure 9 Return to the main screen and notice that all channels are displayed in blue Figure 9 indic...

Page 13: ...499 1302 www rflambda com Page 13 Figure 9 All Channel Setting 7 IP Address Change With the main screen in local mode you can verify the current IP address and change the IP address by pressing F3 Fig...

Page 14: ...972 499 1302 www rflambda com Page 14 REMOTE CONTROL 1 Port Configuration Software Installation Begin by installing the serial port server driver Open the NE 4110S folder and click neadm_setup_Ver2 1...

Page 15: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 15 Click the Next button The following window opens...

Page 16: ...LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 16 Click the Next button The following window opens Click Install to open the insta...

Page 17: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 17 After the installation is complete the following window opens Click Finish to finalize the installation 2 Port Configurat...

Page 18: ...x 972 499 1302 www rflambda com Page 18 To modify the IP address with the unit connected to the PC via parallel cable begin by opening the Configuration menu and selecting Broadcast Search The system...

Page 19: ...ouble click on the system whose IP address you want to modify NE 4110S in the illustrated example to open its IP Settings window In the Configuration window select the Network tab check the Modify che...

Page 20: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 20 To confirm your selections click OK...

Page 21: ...024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 21 Open Internet Explorer and enter the unit s IP address From the Main Menu open the Serial Settings folder adjust the parameters...

Page 22: ...972 499 1302 www rflambda com Page 22 From the Main Menu open the Operating Settings folder adjust the parameters as necessary click on Submit to confirm your selections and close IE 3 Operating Softw...

Page 23: ...860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 23 Read the text on the screen and click on Next to advance to the next screen Do not re...

Page 24: ...trol Interface Click on the icon 8in8outProgrammableSubsystem exe or choose Start All Programs 8in8out ProgrammableSubsystem exe Because of the test subsystem s access to the LAN the network computer...

Page 25: ...allas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 25 Clicking on Disconnect will disconnect the communication subsystem Click either or to toggle...

Page 26: ...e instructions Set single channel attenuation values In the text box next to each channel ANT1 ANT2 ANT3 etc enter the intended channel attenuation value and click Send to confirm your selection Each...

Page 27: ...767 5998 Fax 972 499 1302 www rflambda com Page 27 Multi channel Attenuation Setting Begin by selecting the channels you intend to set Do this by checking the box to the left of the channel label Then...

Page 28: ...A Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 28 Road through operational settings Click on Visible Port and select the interface to operate by checking the box next to the interface...

Page 29: ...RF Lambda USA LLC 6860 N Dallas Parkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 29 To customize the name of a channel begin by clicking on Tools...

Page 30: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 30 The Frm_Tools window opens Click on Profile The Frm_Profile window opens Use the text box next to the channel label to mo...

Page 31: ...the name will automatically be saved To set an attenuation value for all eight channels simultaneously begin at the 8in8out Programmable Subsystem window Click on Tools As with the channel name custom...

Page 32: ...lephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 32 To set an initialized value for the attenuation open the Frm_Tools window as in the two previous procedures Choose a value from the Initi...

Page 33: ...phone 972 767 5998 Fax 972 499 1302 www rflambda com Page 33 Save and return to the main interface when in the Settings drop down list select a channel click on Iinitiallze later In addition to the se...

Page 34: ...ay Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 34 Click AutoScript run into the automation interface Set the appropriate parameters the first point of Ap...

Page 35: ...TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 35 Point Pause pause point Quit to exit Other buttons Read All to read the current attenuation value of all channels About Sy...

Page 36: ...CUSTOM SCRIPT SETTINGS Run automation script From the primary window select Browse and then navigate to the location of the VBScript Begin the script by clicking on Run R Communication protocol can b...

Page 37: ...rkway Suite 200 Plano TX 75024 USA Telephone 972 767 5998 Fax 972 499 1302 www rflambda com Page 37 ACCESSORIES 1 110V 220V power cable 1pcs 2 CD driver control software user manual 1pcs 3 User manual...

Page 38: ...Get the output port connected to any input port It is used in a power Combiner system LO Lock keyboard of the system LU Unlock keyboard of the system RT Restart system Enter HX and command without spa...

Page 39: ...LF Set Switch The set switch command is used to set a switch to a specifi c port number Syntax SSx y CR LF x switch number y port number Example SS11 8 CR LF Sets switch 11 to port 8 System will retu...

Page 40: ...et the output port connected to any input port It is used in a power Combiner system Syntax ROx CR LF x input port Example RO 1 CR LF Get the output port connected to input 1 System will return RO1 1...