Pin #

Name

Function

Initial State

Description

Applied 

1

Reset

Control

Resets PA when logic LOW is applied and released 

Yes 

2

Driver Disable

Control

LOW

Appling logic HIGH disables driver of amplifiers

Yes

3

Drain Disable

Control

LOW

Applying logic HIGH disables drain of amplifiers 

Yes

4

RF IN Over

Indicator

LOW

Pin will be latched to logic HIGH when input signal is 

over limit

No

5

Temp Over

Indicator

LOW

Pin will be latched to logic HIGH when amplifier is 

driven over temperature

Yes

6

Current Over

Indicator

LOW

Pin will be latched to logic HIGH when drain current 

limit is reached

Yes

7

ID Imbalance

Indicator

LOW

Pin will be latched to logic HIGH when an imbalance 

in the drain current of the combining branches occurs

Yes

8

PA input 

power

Indicator

PA input power is represented by voltage

No

9

PA output 

power

Indicator

PA output power is represented by voltage

No

10

PA output 

reflection 

power

Indicator

PA output reflection power is represented by voltage

No

11

VSWR

Indicator

LOW

Pin will be latched to logic HIGH when output 

reflection is over limit

No

13

+5V

Power Supply 

+5V

+5V DC is supplied for reference 

Yes

14

GND

Ground

GND

Ground

Yes

15

GND

Ground

GND

Ground

Yes

User Control Connector on Rear Panel 

HIGH/LOW voltages are standard TTL signals:

0.0V-0.8V = LOW

2V-5V = HIGH 

Notes:

DB15 cable is configured for power connection port by default(RFCBLADB15)

Male

Summary of Contents for REMC18G40GC

Page 1: ...ical Supply Voltage 110V 220V AC Typical Applications Wireless Infrastructure Military Aerospace Test and Measurement Parameter Min Typ Max Units Frequency Range 18 40 GHz Gain 48 50 dB Gain Flatness...

Page 2: ...edure Environmental Specifications and Test Standards Parameter Description Operational Temperature 0 50 Ambient Temperature Storage Temperature 40 85 Thermal Shock 0 50 5 Cycles 10 hours Random Vibra...

Page 3: ...n with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Page 4: ...EMC Equipment User Manual Front Panel Rear Panel ON OFF switch Power Indicator Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Instrument AC power supply switch Fuse Holder Main AC conn...

Page 5: ...nate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration is...

Page 6: ...election Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on fr...

Page 7: ...Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when an imbalance in the drain current of the com...

Page 8: ...with such information is entirely with the user All information contained herein is subject to change without notice Customers should obtain and verify the latest relevant information before placing o...

Reviews: