REMC18G40GC

Rev 1. 02-02-2021

Instrument temperature

RF output attenuation (change with adjustment knob)

RF input signal center frequency

Instrument RF output power

Switches On or Off for instrument RF output port

Indicates instrument RF output status. It will display:

Output is Ready to Turn on or RF Output is ON

Press “Menu” on keypad to enter instrument functions 

selection menu

Instrument Function Selection Page

Instrument Status Display Page

To enter this function selection page, press “Menu” on front 

panel keypad while the instrument is showing the status page.
Press the corresponding number on front panel keypad to 

select:

[1] Calibrate

” calibrates the instruments. 

[2] Frequency

” enters RF input signal center frequency. 

[3] RF ON/OFF

” switches the RF output port on or off.

[4] Reset

” Restarts the instrument (Turns RF output off)

[5] Status

” enters instrument status display page.

[6] Product Info

” displays product part number and serial 

number

All action functions will ask for confirming execution when selected from function selection menu.

User can set a constant gain for the unit. Equipment will 

automatically adjust the gain at certain frequency

Summary of Contents for REMC18G40GC

Page 1: ...ical Supply Voltage 110V 220V AC Typical Applications Wireless Infrastructure Military Aerospace Test and Measurement Parameter Min Typ Max Units Frequency Range 18 40 GHz Gain 48 50 dB Gain Flatness...

Page 2: ...edure Environmental Specifications and Test Standards Parameter Description Operational Temperature 0 50 Ambient Temperature Storage Temperature 40 85 Thermal Shock 0 50 5 Cycles 10 hours Random Vibra...

Page 3: ...n with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Page 4: ...EMC Equipment User Manual Front Panel Rear Panel ON OFF switch Power Indicator Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Instrument AC power supply switch Fuse Holder Main AC conn...

Page 5: ...nate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration is...

Page 6: ...election Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on fr...

Page 7: ...Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when an imbalance in the drain current of the com...

Page 8: ...with such information is entirely with the user All information contained herein is subject to change without notice Customers should obtain and verify the latest relevant information before placing o...

Reviews: