Self Calibration Screen

Instrument Protection Alarms

The front panel LCD screen will display the error code or error message when instrument self protection is 

triggered. Front panel alarm indicator will light up.
To eliminate the error code, press “RESET” on front panel keypad to reboot the instrument and clear the alarms.
If error code can not be eliminated after reboot, please contact [email protected]

Calibration is may be recommended

[1] Calibrate

” to execute instrument self calibration 

process.

[2] Reset

” to reboot the instrument.

*Please turn OFF RF input power, and terminate the RF 

output port while applying calibration function

Switching On Instrument

Please follow the instructions on the front panel LCD screen after switching on the power.
Press “1” on keypad to continue.

Front Panel LCD Screen Display 

Summary of Contents for REMC18G40GC

Page 1: ...ical Supply Voltage 110V 220V AC Typical Applications Wireless Infrastructure Military Aerospace Test and Measurement Parameter Min Typ Max Units Frequency Range 18 40 GHz Gain 48 50 dB Gain Flatness...

Page 2: ...edure Environmental Specifications and Test Standards Parameter Description Operational Temperature 0 50 Ambient Temperature Storage Temperature 40 85 Thermal Shock 0 50 5 Cycles 10 hours Random Vibra...

Page 3: ...n with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Page 4: ...EMC Equipment User Manual Front Panel Rear Panel ON OFF switch Power Indicator Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Instrument AC power supply switch Fuse Holder Main AC conn...

Page 5: ...nate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration is...

Page 6: ...election Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on fr...

Page 7: ...Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when an imbalance in the drain current of the com...

Page 8: ...with such information is entirely with the user All information contained herein is subject to change without notice Customers should obtain and verify the latest relevant information before placing o...

Reviews: