RF-LAMBDA USA            www.rflambda.com   

Sales: [email protected]       Technical : [email protected]

W

ide B

an

d E

M

C B

en

ch

top

 Pow

er A
mp

lifier 

 18

GH

z ~ 

40

GH

z

REMC18G40GC

Rev 1. 02-02-2021

Operating Voltage

230VAC

RF Input Power 

+5dBm

Step 1

Connect input and output with 50 Ohm 

source/load. ( in band VSWR<1.9:1 or 

>10dB return loss) 

Step 2

Turn on AC power

Step 3

Enable RF output

Power OFF Procedure

Step 1

Turn off RF output power

Step 2

Turn Off AC power

Step 3

Disconnect input and output

Absolute Maximum Ratings

Biasing Up Procedure

Environmental Specifications and Test Standards

Parameter

Description

Operational Temperature

0

~+50

(Ambient Temperature)

Storage Temperature

-40

~+85

Thermal Shock

0

+50

(5 Cycles / 10 hours)

Random Vibration

MIL-STD-202G

Table 214-I, Test Condition Letter C

1.5 Hours Per Axis

High Temperature Burn In

Tempe50

for 72 Hours

Shock

1. Weight >20g, 50g half sine wave for 11ms, Speed variation 3.44m/s

2. Weight <=20g, 100g Half sine wave for 6ms, Speed variation 3.75m/s

3. Total 18 times (6 directions, 3 repetitions per direction). 

Altitude

Standard: 30,000 Ft (Epoxy Sealed Controlled Environment)

Optional: Hermetically Sealed (60,000 ft. 1.0 PSI min)

Hermetically Sealed 

(Optional)

MIL-STD-883 (For Hermetically Sealed Units)

Summary of Contents for REMC18G40GC

Page 1: ...ical Supply Voltage 110V 220V AC Typical Applications Wireless Infrastructure Military Aerospace Test and Measurement Parameter Min Typ Max Units Frequency Range 18 40 GHz Gain 48 50 dB Gain Flatness...

Page 2: ...edure Environmental Specifications and Test Standards Parameter Description Operational Temperature 0 50 Ambient Temperature Storage Temperature 40 85 Thermal Shock 0 50 5 Cycles 10 hours Random Vibra...

Page 3: ...n with poor loads is discouraged If prolonged operation with poor or unknown loads is expected an external device such as an isolator or circulator should be used to protect the amplifier Ensure that...

Page 4: ...EMC Equipment User Manual Front Panel Rear Panel ON OFF switch Power Indicator Alarm Indicator Keypad Gain Adjustment Knob RF Output RF Input Instrument AC power supply switch Fuse Holder Main AC conn...

Page 5: ...nate the error code press RESET on front panel keypad to reboot the instrument and clear the alarms If error code can not be eliminated after reboot please contact support rflambda com Calibration is...

Page 6: ...election Page Instrument Status Display Page To enter this function selection page press Menu on front panel keypad while the instrument is showing the status page Press the corresponding number on fr...

Page 7: ...Indicator LOW Pin will be latched to logic HIGH when drain current limit is reached Yes 7 ID Imbalance Indicator LOW Pin will be latched to logic HIGH when an imbalance in the drain current of the com...

Page 8: ...with such information is entirely with the user All information contained herein is subject to change without notice Customers should obtain and verify the latest relevant information before placing o...