IndraControl L40
Connections and Interfaces
7-17
DOK-CONTRL-IC*L40*****-PR03-EN-P
7.6 Function
Modules
Overview
To its left, the IndraControl L40 is provided with a functional module
connector that can be used to connect up to four extension modules. For
this, please observe the installation notes of the IndraControl L40 in the
corresponding chapter.
This 120-pin connector is a Bosch Rexroth PC104
Plus
connector where
the PCI signals as well as additional system-specific signals are applied.
In other words, only the function modules especially developed for the
IndraControl L40 can be connected to this connector.
For the appropriate cables to connect the IndraControl with the function
modules please refer to section "Interface Cables" as of page 11-6.
Note:
The single function modules are not supported by every
system! For information on which function modules are
supported by the used system, please refer to the particular
system-specific manual.
Technical Data
The function modules are supplied from the internal voltage of the
IndraControl L40.
Function module
Consumption
Current
consumption
Power
consumption
from 3.3 V:
300 mA
1.0 W
CFL01.1-Y1 SRAM
Total power consumption:
1.0 W
from 3.3 V:
from 24 V (DeviceNet voltage):
400 mA
55 mA
1.4 W
1.4 W
CFL01.1-V1 DeviceNet Master
Total power consumption:
2.8 W
from 3.3 V:
500 mA
1.65 W
CFL01.1-P1 Profibus master
Total power consumption:
1.65 W
from 3.3 V:
from 5 V:
270 mA
230 mA
0.9 W
1.15 W
CFL01.1-R3 Sercos III
Total power consumption:
2.05 W
from 3.3 V:
from 5 V:
150 mA
360 mA
0.5 W
1.8 W
CFL01.1-Q2 Cross Communication
Total power consumption:
2.3 W
from 3.3 V:
90 mA
0.3 W
CFL01.1-E2 Fast I/O
Total power consumption:
0.3 W
from 3.3 V:
from 5 V:
400 mA
55 mA
1.4 W
1.4 W
CFL01.1-N1 cam switch
Total power consumption:
2.8 W
Fig. 7-27:
Current and power supply
Power Supply
Current and Power Supply
Buy: www.ValinOnline.com | Phone: 844-385-3099 | Email: [email protected]