17/17
Bosch Rexroth Canada ı August.2018 ı Revision 2.0
10 Warning
This glass LCD touch screen display has been extensively tested and validated against its
intended use. This glass could crack and break if the display is dropped on to a hard
surface or receives a substantial impact. If the glass chips or cracks, discontinue use and
contact Bosch Rexroth Canada to have it replaced - do not touch or attempt to remove the
broken glass. Any misuse/abuse causing damage, whether intended or not, will become the
sole responsibility of the owner/buyer which will render the warranty of this product, void.
Notes:
ANTI-ICING PULSES/GAL TOO HIGH
52
Check anti-icing sensor, and recalibrate
SPNR WIDTH AT 0 RPM TOO LOW
53
Check spinner sensor, and recalibrate
SPNR WIDTH PER RPM TOO LOW
54
Check max width, and recalibrate
GATE MOVEMENT TOO LOW
55
Range too small (Low -> High)
GATE ZERO IN MANUAL
56
Manual Gate set to 0
GATE AT CALIBRATION TOO LOW
57
Calibrated gate needs tob a non-zero value
SPINNER SENSOR PULSES TOO LOW 58
Spinner sensor pulses 0 or too low
CONV SENSOR PULSES TOO LOW
59
Conv sensor pulses 0 or too low
SPINNER OUTPUT RANGE TOO LOW
60
Range between spn Min and Max too small
CONV OUTPUT RANGE TOO LOW
61
Range between Conv Min and Max too small
CROS CONV1 OUTPUT RANGE LOW
62
Range between Cros1 Min and Max too small
CROS CONV2 OUTPUT RANGE LOW
63
Range between Cros1 Min and Max too small
PREWET OUTPUT RANGE LOW
64
Range between prewet Min and Max too small
ANTI-ICING OUTPUT RANGE LOW
65
Range for anti-icing Min to Max too small
JOY1 OUTPUT RANGE TOO LOW
66
Range between Joy1 Min and Max too small
JOY2 OUTPUT RANGE TOO LOW
67
Range between Joy2 Min and Max too small
REQUIRED CONV RPM TOO HIGH
68
Setpoints too high, incorrect wt/rev
REQUIRED PREWET FLOW TOO
HIGH
69
Setpoints too high, incorrect pulses/gallon
REQUIRED ANTI-ICING FLOW TOO HI 70
Setpoints too high, incorrect pulses/gallon