16/17
Bosch Rexroth Canada ı August.2018 ı Revision 2.0
UNLOAD NOT ALLOWED
21
Vehicle needs to be stationary
BB3 SYSTEM ERROR
22
Check if RCE present, Reboot
RC COMMUNICATION ERROR
23
Comm failure between display and RC
RCE COMMUNICATION ERROR
24
Comm failure between RC and RCE
JOY 1 COMMUNICATION ERROR
25
Comm failure between RC and Joystick 1
JOY 2 COMMUNICATION ERROR
26
Comm failure between RC and Joystick 2
NO GATE SENSOR
27
Check gate sensor, cable break
GATE POSITION ZERO
28
Gate closed in READBACK mode
NO GROUND SPEED SIMULATION
29
Speed Simulation mode stopped
UNDER APPLICATION-SPINNER
30
Spinner not able to reach desired RPM
UNDER APPLICATION-CONVEYOR
31
Rate or speed too high, incorrect calibration
UNDER APPLICATION-PREWET
32
Rate or speed too high, incorrect calibration
UNDER APPLICATION-ANTI-ICING
33
Rate or speed too high, incorrect calibration
OVER APPLICATION-COVEYOR
34
Min null or gate too high,
OVER APPLICATION-PREWET
35
Min null too high, rate too low
OVER APPLICATION-ANTI-ICING
36
Min null too high, rate too low
CALIB:GND SPD PULSES TOO LOW
37
Too few or no pulses, recalibrate
SPINNER MAX RPM TOO LOW
38
Bad or no sensor
CONVEYOR MAX RPM TOO LOW
39
Bad or no sensor
PREWET MAX HZ TOO LOW
40
Too few pulses, or sensor failed
ANTI_ICING MAX HZ TOO LOW
41
Too few pulses, or sensor failed
WRONG SPINNER CONTROL MODE
42
Auto null not allowed for MANUAL mode
SPARE
43
Not used
WRONG PREWET CONTROL MODE
44
Auto-null or volume calibration not allowed
WRONG ANTI-ICING CONTROL MODE 45
Check Anti-icing or Cross-Conv modes
WRONG CROSS-CONVEYOR MODE
46
Check Cross-Conv mode setting
WT/REV TOO LOW
47
Check conveyor sensor, and calibrate again
WT/REV TOO HIGH
48
Check conveyor sensor, and calibrate again
PREWET PULSES/GAL TOO LOW
49
Check prewet sensor, and calibrate again
PREWET PULSES/GAL TOO HIGH
50
Check prewet sensor, and calibrate again
ANTI-ICING PULSES/GAL TOO LOW
51
Check anti-icing sensor, and calibrate again
Warning Messages
#
Suggested Solution