Appendix M • Falk Quadrive
Shaft Mounted Drives Model A
(Page 50 of 52)
Sizes 5307 and 5315
378-200
(PN-2128394)
Rexnord
January 2019
3001 W. Canal St., Milwaukee, WI 53208-4200 USA
Supersedes 04-17
Telephone:
414-342-3131
Fax:
414-937-4359
www.rexnord.com
Electric Fan Installation
NOTE
: Electric Fan Installation only applies to sizes
5307 and 5315
INTRODUCTION
The following instructions apply to the installation of electric
fans Refer to Figure 1 for fan mounting location
ASSEMBLY INSTRUCTIONS
WARNING:
Consult applicable local and national safety
codes for proper guarding of rotating members.
Lock out power source and remove all external loads from
drive before servicing drive or accessories.
1 Remove V-belt guard assembly
2 Insert four 1 25” (32 mm) long cap screws through fan
mounting holes in shroud with threaded portion of cap
screw away from drive Secure cap screws to shroud
with flat washers and hex nut See Figure 2
3 Mount shroud to drive using spacers and hardware
See Figure 1
4 Assemble V-belt guard bracket
5 Position the electric fan panel on the remaining
threaded portion of the cap screws and secure it to the
shroud with four locknuts See Figure 2
6 Remove the condensation plug from bottom of the fan
7 Finish installing V-belt guard assembly per installation
instruction in Appendix L
8 Connect electric fan to power source per local and
national electrical codes
.25" x 1.25"
CAP SCREW
HEX NUT
LOCKNUT
SHROUD
(2) FLAT WASHERS
ELECTRIC FAN PANEL
1.45" LONG (4307)
0.62" LONG (4315)
MOTOR MOUNT
(SHOWN FOR REFERENCE)
SPACER
CAP SCREW
.625” x 2.50” (4307)
.625“ x 1.50” (4315)
LOCK WASHER
SHROUD
ELECTRIC FAN
SPACER
.32” LONG
CAP SCREW
.625” x 1.25”
LOCK WASHER
V-BELT GUARD BRACKET
(SHOWN FOR REFERENCE)
Figure 1
Figure 2