WINTER USE INSTRUCTIONS

Rexener hot tub products have been designed for tough Northern conditions.  Hot tub kits are frost-proof 

when used and maintained correctly.

Correct use of the drainage valve in winter

During winter use, it is important to keep the pool’s drainage pipe empty, so that it does not freeze. When 

you use the pool’s bottom plug, the drainage pipe remains empty, and the problems caused by freezing 

are thus avoided. When drainage pipes are equipped with a drainage valve, it is important to keep the 

drainage valve open or at least 45 degrees in the open position during the winter. If the drainage valve 

is closed, water can remain inside the drainage valve and pipe, causing damage when it freezes. A pool 

bottom plug must be used in all hot tub versions.

Winter storage of heaters

• 

Drain the pool and heating devices with pipes completely

• 

Cover the pool and accessories so that they do not touch snow and ice directly.

• 

Keep the plug delivered with the pool for later use.

• 

Ensure that snow does not accumulate in the support frame or pool of the hot tub kit.

• 

PLEASE NOTE! THE WARRANTY DOES NOT COVER DAMAGE CAUSED BY FREEZING

Using heaters in winter

The hot tub kit can also be used in winter. Model-specific differences and precautions must be observed 

during winter use.

In winter use, it is important to consider especially blocks caused by freezing in the water-flow channels. 

Please note! Water must not be allowed to freeze in either heating mode (wood stove/REXENER PR200 

water heater). Maintain the water temperature so that it does not freeze.

The wood stove (REXENER Silence) must not be used if ice is detected in the water-flow piping or stove, 

and water cannot circulate normally. If you notice that the water flow channels are frozen, the stove 

should be removed and taken to a warm space to thaw.

The REXENER PR200 water heater (REXENER Aurora/Polar) is excellent for winter use. The most important 

thing is to ensure that the flow channels are not blocked, and water flows normally.

If you notice that a flow channel has frozen, it must be thawed before starting the pump and heater. 

During winter use, it is recommended to add enough warm water into the pool to open the pump and 

flow channels, and allow water to flow freely in the piping.

If the circulation pump freezes, it can be started by pouring 1 L of warm water into the circulation pump. 

After this, the pool can be filled with water normally. You can maintain the water temperature at ten 

degrees, for example, and heat the water quickly to an optimal bathing temperature.

Summary of Contents for Aurora

Page 1: ...INSTALLATION AND OPERATION GUIDE REXENER Polar REXENER Aurora REXENER Silence ...

Page 2: ...ove Installing the smoke pipes to the wood stove Water hoses of the wood stove 13 REXENER Aurora Polar installation instructions Connecting the protective case and hot tub 14 Operating instructions for accessories LED pool lights REXENER Aurora Polar Whirlpool bath kit REXENER Polar 15 Operating instructions for the wood stove Rexener Silence Before heating General instructions for heating a wood ...

Page 3: ...vered on its own pallet packed wrapped in plastic and tied to the pallet REXENER Aurora Polar both the technical parts and the protective case are delivered on their own pallet packed wrapped in plastic and tied to the pallet Receiving the hot tub kit The pool must be emptied of any loose uninstalled accessories before turning the hot tub kit around Approximately 4 to 6 persons should carry the po...

Page 4: ...he ground and supported When the product is moved to its appropriate installation place consider the need for an external lifting device if the installation of the product in the desired place is impossible without such a device Safe use of the pool Encourage all users of the pool to learn how to swim Knowledge of first aid measures and resuscitation improves safety First aid can save a person s l...

Page 5: ...n extension cord but instead to an earthed socket located in an appropriate place You must not touch the socket when you are wet The box s electric cord must be connected as appropriate to a grounded socket protected against residual current Only use official parts provided by the manufacturer when servicing the product Read the operating instructions before use The condition of the equipment and ...

Page 6: ...water heater REXENER Aurora and Polar REXENER Aurora and Polar hot tubs are equipped with a protective case The smoke pipe of the REXENER PR200 water heater installed through the protective case s cover gets hot when the device is running The minimum distance from the water heater REXENER PR200 s smoke pipe from other structures and or combustible materials measured upwards from the chimney s open...

Page 7: ...e Aurora Polar 570 x 850 x 960 mm Protective case weight Aurora Polar ca 100 kg Max Depth 1 000 mm Pool volume ca 1 500 l Dry weight of the pool ca 200 kg Pool weight when filled ca 2 000 kg Max users 4 8 persons Frame material Finnish spruce Standards EN17125 500 mm 600 mm 400 mm REXENER Silence REXENER Aurora Polar ...

Page 8: ...onnectable with a plug Remote control for the lights A REXENER PR200 water heater installed in the protective case A Rexener mass filter and circulation pump installed in the protective case Heat insulation of the frame and protective case REXENER Polar Pool kit assembled wooden frame with support structures panelled Arctic white or Gabro Black coloured glass fibre pool Protective case made of spr...

Page 9: ...y 3 hours The hot tub should be filled according to the number of users and considering the maximum filling volume ca 1 500 l If the heating device wood stove REXENER PR200 water heater is not on use the water must be emptied from the heating device In winter use it is especially important that there is no water left in the system as this could cause damage The warranty of the manufacturer and imp...

Page 10: ...nd frame for example When installed this way the bottom frame of the tub and box is left slightly above the ground and the air also circulates under the frame The wood stove REXENER Silence and the protective case containing technical parts REXENER Aurora Polar must be installed on an even surface and at the same level as the hot tub kit frame s bottom The base must be able to carry ca 2 500 kg Wh...

Page 11: ...easily into place When embedding a REXENER Silence hot tub the space needed for the wood stove must be considered The wood stove must be separated from the terrace s wooden parts and safety distances must be taken into account In connection with REXENER Aurora Polar hot tubs take into account the protective case that is assembled on the hot tub s side The bottom of the protective case must be at t...

Page 12: ...ater before you start heating Smoke pipes of the wood stove The smoke pipes included in the hot tub are made of stainless steel The package includes 2 x 1 000 mm interconnectable smoke pipes One of them has a pipe hat The smoke pipes are installed inside each other by the seams and placed on top of the stove s smoke hole Installing the smoke pipes to the wood stove The lower pipe is a straight pip...

Page 13: ...d 6 Install the water heater s smoke pipe Attach the pipe to the heater with three screws 7 Install the plate intended around the smoke pipe feed through and attach it with four screws 8 The protective case includes a pre installed electric cord The plug is pulled out through the hole 9 All electric cables lights the whirlpool bath kit only REXENER Polar and the REXENER PR200 water heater are conn...

Page 14: ...he whirlpool bath kit have been pre installed The pump and electric cord of the whirlpool bath kit are located inside the frame close to the edge on the box s side From there it is easy to connect them to the pre installed socket in the box The button of the whirlpool bath kit is installed at the pool s edge on the side of the step The whirlpool bath kit is turned on and off by pressing the button...

Page 15: ...may come out of the front corners This is condensation water and it will stop when the stove has been used a few times Mix the water in the pool during heating to achieve an even temperature Draining the wood stove and pool Empty both the pool and stove of water Open the stove s drainage plug at its front corner and open the pool s drainage valve and plug The stove s fire must be extinguished and ...

Page 16: ...d the pool are not leaking If you detect a leak the connections must be tightened enough to stop it The pool must be filled or at least the leg space must be filled to the lower rim of the seat before starting the heater pump Fill the fuel tank with biodiesel diesel or red diesel before start up The REXENER PR200 water heater is started by pressing the start button To regulate the temperature use ...

Page 17: ...P10616 S The warranty granted for the pool does not cover faults caused by erroneous use such as corrosion of the pool or its accessories or surface damage You can find the detailed warranty terms at www rexener com When emptying the pool the water must be directed into the appropriate waste water system When using chemicals the water must be drained to the sewer to prevent contamination Treatment...

Page 18: ...t tub kit can also be used in winter Model specific differences and precautions must be observed during winter use In winter use it is important to consider especially blocks caused by freezing in the water flow channels Please note Water must not be allowed to freeze in either heating mode wood stove REXENER PR200 water heater Maintain the water temperature so that it does not freeze The wood sto...

Page 19: ...rranty Additional warranty Glass fibre pool element 5 year warranty 5 years 10 years in total Stove TK 35 3 year warranty Rexener PR200 3 year warranty Support frame wooden 3 year warranty Pool lights and jet system 3 year warranty the additional warranty is granted to customers who have registered for the warranty For the registration of the warranty and detailed instructions please go to www rex...

Page 20: ...53 773 70 info rexnordic com FINLAND 040 180 11 11 info rexnordic com SWEDEN 072 200 22 22 info rexnordic com NORWAY 0400 66 16 norge rexnordic com EUROPE 358 40 180 11 11 info rexnordic com WE ARE HERE FOR YOU ...

Reviews: