Technical data
58 Operating instructions RLD
ELTROPLAN
-
REVCON
Elektrotechnische Anlagen GmbH
3.10
Harmonic filter module RHF-RA module
To decrease the low frequency harmonic back effects to mains a filter module REVCON
RHF-RA can be connected to the power feedback unit according figure 4.4.1.3 and
4.4.1.4* In the tables 3.11.1.1 to 3.12.1.4 the corresponding filter modules are listed for the
power feedback unit. Provided that the total harmonic distortion of the unaffected mains
voltage THD U is smaller as 2% and the ratio of short circuit power and installed power
R
SCE
is at least 66, the THD I of the mains current of the power feedback unit is reduced to
typical 16%.
*
Only in connection with option EST
3.11
RHF-RA module RLD B0
REVCON
®
- type
Ordering code
RHF- module
REVCON
®
-
item number
Case type
Fan
RLD B0 7-400-50-0-A
RHF-RA 10-400-50-20-A
25070001
X1
-
RLD B0 13-400-50-0-A
RHF-RA 22-400-50-20-A
25070003
X2
inside
RLD B0 22-400-50-0-A
RHF-RA 35-400-50-20-A
25070005
X3
inside
RLD B0 33-400-50-0-A
RHF-RA 58-400-50-20-A
25070008
X4
inside
RLD B0 45-400-50-0-A
RHF-RA 72-400-50-20-A
25070009
X4
inside
RLD B0 70-400-50-230-A RHF-RA 101-400-50-20-A
25070011
X5
inside
RLD B0 90-400-50-230-A RHF-RA 144-400-50-20-A
25070012
X6
inside
RLD B0 135-400-50-230-A RHF-RA 217-400-50-20-A
25070014
X7
inside
RLD B0 160-400-50-230-A RHF-RA 252-400-50-20-A
25070015
X7
inside
RLD B0 200-400-50-230-A RHF-RA 304-400-50-20-A
25070016
X7
inside
RLD B0 250-400-50-230-A RHF-RA 380-400-50-20-A
25070018
X7
inside
RLD B0 345-400-50-230-A
On request
On request
On request
On request
Table 3.11.1.1
REVCON
®
- type
Ordering code
RHF- module
REVCON
®
-
item number
Case type
Fan
RLD B0 22-460-60-0-A
RHF-RA 31-460-60-20-A
25070024
X3
inside
RLD B0 33-460-60-0-A
RHF-RA 48-460-60-20-A
25070026
X3
inside
RLD B0 45-460-60-115-A RHF-RA 60-460-60-20-A
25070027
X4
inside
RLD B0 70-460-60-115-A RHF-RA 95-460-60-20-A
25070029
X5
inside
RLD B0 90-460-60-115-A RHF-RA 118-460-60-20-A
25070030
X5
inside
RLD B0 110-460-60-115-A RHF-RA 154-460-60-20-A
25070031
X6
inside
RLD B0 125-460-60-115-A RHF-RA 183-460-60-20-A
25070032
X6
inside
RLD B0 140-460-60-115-A RHF-RA 183-460-60-20-A
25070032
X6
inside
RLD B0 160-460-60-115-A RHF-RA 231-460-60-20-A
25070033
X7
inside
RLD B0 230-460-60-115-A RHF-RA 291-460-60-20-A
25070034
X7
inside
RLD B0 280-460-60-115-A RHF-RA 355-460-60-20-A
25070035
X7
inside
RLD B0 325-460-60-115-A RHF-RA 436-460-60-20-A
25070037
X8
inside
RLD B0 375-460-60-115-A
On request
On request
On request
On request
Table 3.11.1.2