![Reson SeaBat 8101 Operator'S Manual Download Page 105](http://html1.mh-extra.com/html/reson/seabat-8101/seabat-8101_operators-manual_1444854105.webp)
Interface Specification Document
6.3.1.43 CTD Baud Rate
•
DESCRIPTION:
This message controls the IN baud rate for downlink port 1. The port IN receives CTD
data.
•
SYNTAX:
*SVBR,N<CR><LF>
•
PARAMETERS:
N – Baud rate. Different speeds are 1200, 2400, 4800, 9600, 19200, 38400, 57600,
115200.
•
EXAMPLE:
*SVBR,9600<CR><LF> This example sets the IN baud rate on downlink port 1 to 9600.
6.3.1.44 Version
•
DESCRIPTION:
This message returns the wet end and dry end software version.
•
SYNTAX:
*SVER<CR><LF>
•
PARAMETERS:
N/A
•
EXAMPLE:
*SVER<CR><LF>
The message returns *SVER,????-????-????,????-????-????<CR><LF>, where the
??? are the version numbers.
6.3.1.45 Synchronization
•
DESCRIPTION:
This message selects the synchronization method between the 81-P processors.
•
SYNTAX:
*SYNC,N<CR><LF>
•
PARAMETERS:
N – Synchronization Value.
0 – Stand-alone.
1 – Slave.
2 – Master.
•
EXAMPLE:
*SYNC,0<CR><LF>
The example sets the 81-P processor to stand-alone.
6.3.1.46 Head Tilt (bathy only)
•
DESCRIPTION:
This message sets the head tilt angle.
•
SYNTAX:
*TILT,N<CR><LF>
•
PARAMETERS:
N – Tilt angle from –180
°
to +180
°
.
•
EXAMPLE:
*TILT,-1<CR><LF>
The example sets the tile angle to -1
°
.
______________________________________________________________________
SeaBat 8101 Operator's Manual
6-19
(ISD Rev 1.23) Version 3.02