en
19
Installation
Indications,
functions and options
Messages
Commissioning
Operation and function
3.3 Control lamp
The controller is equipped with a multicolour LED in the centre of the Lightwheel
®
,
indicating the following states:
Colour
Permanently shown
Flashing
Green
Everything OK
Manual mode: at least one relay HAND ON / mini-
mum speed / maximum speed
Red
Sensor line break, sensor short circuit, flow rate
monitoring, overpressure, low pressure
Yellow
Holiday function
active
∆
T too high, night circulation, FL/RE interchanged,
store maximum temperature exceeded
Red /
green
Manual mode: at least one relay HAND OFF
3.4 Menu structure
Adjustment values
DT O
DT F
DT S
S SET
S MAX
SMAXS
…
Menu level
BALAN
Adjustment level
SYS
LOAD
COL
…
Status level
TCOL
TCOL2
TSTB
TSTT
…
Balance values
h R1
h R2
MAXS1
MINS1
…
The menu structure of the controller consists of 2 levels: the status level and the
menu level.
The status level consists of different display channels which indicate display values
and messages.
The menu level consists of the balance values menu and several menu items each
of which consists of sub-menus and adjustment channels. In order to activate or
deactivate a function, it must be selected in the menu level. The display changes to
the adjustment menu in which all adjustments required can be carried out.
Note
Some of the menu items depend on the selected system and the adjusted
options. Therefore, they are only displayed if they are available.
Note
The abstract from the menu structure is for information on the structure
of the controller menu and is therefore not complete.
3.5 Selecting menu points and adjusting values
During normal operation of the controller, the display shows the status level with
the adjustment channels. If no button is pressed for 1 min, the display illumination
goes out. If no button is pressed for further 3 min, the display indicates the status
level.
Press any key to reactivate the display illumination.
In order to scroll through the display channels, turn the Lightwheel
®
.
Accessing the adjustment level:
Î
Press the right button (
✓
) for approx. 3 s.
The display changes to the adjustment level. All menus contain adjustment channels
and are marked with PUSH below the menu item.
Î
In order to access the desired menu, press the right button (
✓
)
Note
Only if the installer code is entered (see page 51), will the adjustment
level be accessible.
Summary of Contents for DeltaSol SLL
Page 58: ...58 en ...
Page 59: ...59 en ...