en
13
Installation
Indications,
functions and options
Messages
Commissioning
Operation and function
System 6: 2-store solar system with pump logic
The controller compares the temperature at sensor S1 to the temperatures at
sensors S2 and S4. If the measured temperature differences are higher than the ad-
justed switch-on temperature differences, the pump (R1 and/or R2) will be activat-
ed and the corresponding store will be loaded up to the adjusted store maximum
or set temperature respectively at most. The priority logic effects prior loading of
store 1.
System 6 system screen
R2
R1
S4
S2
S1
N
N
N
N
10
11
2
3
3
2
2
3
VBus
VBus
V4
0
S4
S3
GND
Sensors
Relais
S2
S1
N
R2
R1
L
R4
R4
R2
R1
L
1
2
3
4
5
6
7
8
9
PWM
A
PWM
B
Temperature sensors
S1
Temperature collector
1 / GND
S2
Temperature store
base
2 / GND
S3
Free
3 / GND
S4
Temperature store
2 base
4 / GND
Relay
R1
Solar pump store
R1 / N / PE
R2
Solar pump store 2
R2 / N / PE
R4
Free
R4 / R4
Mains