Display of temperatures at S3, S4 and S5
S3, S4, S5
Sensor temperatures
Display range: -40 … +260 °C
Indicates the current temperature at the corresponding additional sensor
(without control function).
• S3 : Temperature sensor 3
• S4 : Temperature sensor 4
• S5 : Temperature sensor 5
Note:
In systems with return preheating, S3/S5 is used as the heat source
sensor TSTR.
Display of further temperatures
TSFB,
etc.
Further measured temperatures
Indication range: -40 … +260 °C
Indicates the current temperature at the corresponding sensor. The display of
these temperatures depends on the system selected.
• TSFB
: Temperature solid fuel boiler
• TRET
: Temperature heating return
• TSTR
: Temperature store return preheating
• TFHQM : Temperature flow (HQM)
• TRHQM : Temperature return (HQM)
• TAH
: Temperature afterheating
• TSFL
: Temperature solar flow
• TSRE
: Temperature solar return
• TVFS
: Temperature flow rate sensor
• TRPS
: Temperature pressure sensor
Display of flow rate
L/ ,
G/
Flow rate
Indication range: 0 … 9999 l/h
Indicates the measured current flow rate. The flow rate value is used for cal-
culating the heat quantity supplied (V40 / VFS / Flowrotor).
Display of pressure
BAR
Pressure
Display range: 0 … 10 bar
Indicates the current system pressure.
Note:
The pressure will only be indicated if an RPS sensor is used.
Display of speed
1%, 2%, 3%
Current pump speed
Indication range: 20 … 100 % (standard pump / HE pump)
Indicates the current speed of the corresponding pump.