System 15: 2-store solar system with valve logic and heat exchange control
The controller compares the temperature at sensor S1 to the temperatures at
sensors S2 and S4. If the measured temperature differences are higher than the
adjusted switch-on temperature differences, the pump (R1) will be activated and
the corresponding store will be loaded up to the adjusted store maximum or set
temperature respectively via the valve (R2). The priority logic effects prior loading
of store 1.
Heat exchange control to an existent store via an additional pump (R3) can be
carried out with another temperature differential function (S3 heat source/S4
heat sink) .
Hydraulic variant 1
Hydraulic variant 3
Hydraulic variant 2
Sensors
S1
Temperature collector
1 / GND
S2
Temperature store
base
2 / GND
S3
Temperature heat
exchange source
3 / GND
S4
Temperature store
2 base and heat
exchange sink
4 / GND
S5
Free
5 / GND
S6
Free
S6
Relay
R1
Solar pump
R1 / N / PE
R2
Valve solar circuit
R2 / N / PE
R3
Store loading pump
R3 / N / PE
R4
Free
R4 /R4
R3
R1
R2
S4
S3
S2
S1
VBus
VBus
S5/V
40
S4
S3
GND
S6
S7
Sensors
Relais
S2
S1
N
R3
R2
R1
L
R4
PW
M
A
0-10
V
PW
M
B
0-10
V
R4
N
N
N
N
R3
R2
R1
L
1
2
3
4
5
6
7
8
9
10
11
2
3
3
2
2
2
3
3
Netz
Mains
Flow direction
when normally open
Summary of Contents for DeltaSol SL
Page 82: ...en 82 82 en...
Page 83: ...en 83 83 en...