11. Maximum store temperature:
Î
Adjust the maximum store temperature. In 2-store
systems, the adjustment has to be carried out for
S2MAX aswell (see page 51).
12. Loading store 1:
Î
Switch on or off the “loading store 1” option (see
page 51).
Note:
“Loading store 1” is only available if a 2-store
system or store loading in layers has been
previously selected in the sub-channel SYS.
13. Loading store 2:
Î
Switch on or off the “loading store 2” option (see
page 51).
Note:
“Loading store 2” is only available if a 2-store
system or store loading in layers has been
previously selected in the sub-channel SYS.
14. Relay control type:
Î
Select the relay control type for REL. Carry out
this adjustment for REL2 and REL3 as well, if
necessary (see page 60).
15. Minimum speed:
Î
Adjust the minimum speed MIN of the relay. Car-
ry out this adjustment for relay 2 and relay 3 as
well, if necessary (see page 60).
Note:
The minimum speed value will not be available
if ONOF has been selected in the sub-channel
REL (REL2, REL3).
16. Maximum speed:
Î
Adjust the maximum speed MAX of the relay.
Carry out this adjustment for relay 2 and relay 3
as well, if necessary (see page 60).
Note:
The minimum speed value will not be avail-
able if ONOF has been selected in the
sub-channel REL (REL2, REL3).
Î
Complete the commissioning menu by
pressing the right button (
):
The controller is then ready for operation and nor-
mally the factory settings will give close to optimum
operation.
Note:
The adjustments carried out during commis-
sioning can be changed anytime in the cor-
responding adjustment channel. Additional
functions and options can also be activated or
deactivated (see page 44).
Set the code to the customer code be-
fore handing over the controller to the
customer.
Commissioning