Instructions to the Homeowner

WARNING

Fire or Explosion Hazard.

Can cause property damage, severe injury, 

or death.

Follow these warnings exactly:

1. Before lighting, smell around the appliance for 

gas. Be sure to smell next to the floor because 

LP gas is heavier than air. If you smell gas:

      a. Turn off the gas supply at the appliance       

service valve. On LP gas systems, turn off       

the gas supply at the gas tank.

      b. Do not light any appliances in the house.

      c. Do not touch electrical switches or use the 

phone.

      d. Leave the building and use a neighbor’s      

phone to call your gas supplier.

       e. If you cannot reach your gas supplier, call       

the fire department.

2. Replace the gas control in the event of any 

physical damage, tampering, bent terminals, 

missing or broken parts, stripped threads, or 

evidence of exposure to heat.

IMPORTANT

Follow the operating instructions provided by 

the heating appliance manufacturer. The 

information below describes a typical control 

application, but the specific controls used and 

the procedures outlined in your appliance 

manufacturer instructions can differ, requiring 

special instructions.

To Turn ON Appliance

STOP! Read the Warnings 
Above Before Proceeding.

1.

The lighting sequence on this appliance is 

automatic; 

do not attempt to manually light the 

main burner.

2.

If the furnace does not come on when the 

thermostat is set several degrees above room 

temperature, set the thermostat to its lowest 

setting to reset the safety control.

3.

Remove the burner access panel if provided on 

your appliance.

4.

Push the on-off switch to the OFF position.

5.

Wait five minutes to allow any gas in the 

combustion chamber to vent. Then if you smell 

gas, STOP! Follow Step 1 in the Warning above. If 

you do not smell gas, continue with the next step.

6.

If you do not smell gas, push the electronic on-off 

switch to the ON position.

7.

Replace the burner access panel.

8.

Reset the thermostat to the desired temperature.

9.

If the appliance does not turn on, turn the gas 

control switch to OFF and contact a qualified 

service technician for assistance.

Turning Off the Appliance

Vacation Shutdown

Set the thermostat to the desired room temperature 

while you are away.

Complete Shutdown

1.

Turn off power to the appliance. 

2.

Turn off the gas supply to the appliance. 

3.

Push the on-off switch to the OFF  position. Appli-

ance will completely shut off. 

4.

Follow the procedure in the Instructions to the 

Homeowner section above to resume normal 

operation.

WEEE Directive:

At the end of their useful life the 

packaging and product should be 

disposed of by a suitable recycling 

centre.

Do not dispose of with normal 

household waste.

Do not burn.

Summary of Contents for VR8215

Page 1: ...6 4 mm Body Pattern Straight through see Table 1 for inlet and outlet size Electrical Ratings Voltage and Frequency 24 Vac 50 60 Hz Current Draw Single Stage 0 5 A Field Wiring Single Stage Two 1 4 in...

Page 2: ...Dust or Grease Accumulation Heavy accumulations of dust or grease can cause the control to malfunction Where dust or grease can be a problem provide covers for the control to limit contamination Heat...

Page 3: ...d pipe that is free from chips If tubing is used make sure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Run pipe or tubing to the control If tubing...

Page 4: ...valve label Fig 4 Typical wiring connections for 24 volt control in S87 Direct Ignition System Fig 5 Typical wiring connections with 24 volt control in S89 Direct Ignition System M27669A 24V 24V GND S...

Page 5: ...to main burner is properly adjusted for complete combustion Follow appliance manufacturer instructions 2 IF CHECKING GAS INPUT BY CLOCKING GAS METER Make certain there is no gas flow through the meter...

Page 6: ...sure all controls operate properly MAINTENANCE WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not disassembly the gas control it contains no replaceable component...

Page 7: ...ctured gas Single Stage Single stage controls with standard and slow opening regulators model numbers with suffix S M T can be converted from one gas to the other with a conversion kit See Table 4 for...

Page 8: ...d the procedures outlined in your appliance manufacturer instructions can differ requiring special instructions To Turn ON Appliance STOP Read the Warnings Above Before Proceeding 1 The lighting seque...

Page 9: ...mm 1 4 po Configuration du corps passage direct reportez vous au Tableau 1 pour conna tre la taille d entr e et de sortie Caract ristiques lectriques Tension et fr quence 24 V c a 50 60 Hz Appel de co...

Page 10: ...tine vitez tout contact avec le r gulateur Lorsque des produits chimiques sont en suspension dans l air comme c est le cas dans le cadre de certaines applications industrielles ou agricoles prot gez l...

Page 11: ...ait tre expos des vapeurs de produits chimiques ou des gouttes d eau Installation de la tuyauterie sur le r gulateur Toute la tuyauterie doit tre conforme aux codes et r glements locaux ou au code nat...

Page 12: ...MM MINIMUM MONT E R GULATEUR DE GAZ ALIMENTATION EN GAZ TUBE HORIZONTAL MONT E MF3077C 2 1 2 2 1 2 TOUS LES COUDES DES TUBES M TALLIQUES DOIVENT TRE LISSES MISE EN GARDE COUPER L ARRIV E DE GAZ PRINC...

Page 13: ...le br leur principal est correctement r gl e pour assurer une combustion totale Suivez les instructions du fabricant de l appareil 2 POUR UNE V RIFICATION DE L ENTR E DE GAZ EN CHRONOM TRANT LE COMPT...

Page 14: ...ut causer des d g ts ou des blessures graves voire mortelles Ne d montez pas le r gulateur gaz car il ne contient pas de composants qui peuvent tre remplac s Toute tentative de d montage de r paration...

Page 15: ...n n cessaire de conversion Reportez vous au Tableau 4 pour plus d informations sur le num ro de pi ce du n cessaire de conversion correspondant 1 Coupez la vanne d alimentation en gaz de l appareil 2...

Page 16: ...c dures d finies par le fabricant de votre appareil peuvent diff rer et n cessiter des instructions sp ciales Pour mettre l appareil en marche ARR TEZ Lisez les avertissements ci dessus avant de conti...