resideo VR8215 Installation Instruction Download Page 3

VR8215S,M,T SINGLE STAGE DIRECT IGNITION GAS CONTROLS

3

69-2253EF—01

Bushings

1.

Remove the seal over the control inlet or outlet.

2.

Apply a moderate amount of good quality pipe 

compound to the bushing, leaving two end threads 

bare. On an LP installation, use compound that is 

resistant to LP gas. See Fig. 1.

NOTE:

 Do not use Teflon tape.

3.

Insert the bushing in the control and carefully 

thread the pipe into the bushing until tight. 

Complete the instructions below for installing the piping, 

installing the control, and connecting the wiring. Make 

sure the leak test you perform on the control after 

completing the installation includes leak testing the 

bushings.

Location

The gas controls are mounted in the appliance vestibule 

on the gas manifold. If this is a replacement application, 

mount the gas control in the same location as the old 

control.

Locate the combination gas control where it cannot be 

affected by steam cleaning, high humidity, or dripping 

water, corrosive chemicals, dust or grease accumulation 

or excessive heat. 

To assure proper operation, follow these guidelines:

• Locate gas control in a well-ventilated area.

• Mount gas control high enough above cabinet bottom 

to avoid exposure to flooding or splashing water.

• Assure the ambient temperature does not exceed the 

ambient temperature ratings for each component.

• Cover gas control if appliance is cleaned with water, 

steam, or chemicals or to avoid dust and grease 

accumulation.

• Avoid locating gas control where exposure to 

corrosive chemical fumes or dripping water are likely.

Install Piping to Control

All piping must comply with local codes and ordinances 

or with the National Fuel Gas Code (ANSI Z223.1, NFPA 

No. 54), whichever applies. Tubing installation must 

comply with approved standards and practices.

1.

Use new, properly reamed pipe that is free from 

chips. If tubing is used, make sure the ends are 

square, deburred and clean. All tubing bends must 

be smooth and without deformation.

2.

Run pipe or tubing to the control. If tubing is used, 

obtain a tube-to-pipe coupling to connect the 

tubing to the control.

3.

Install a sediment trap in the supply line to the 

control. See Fig. 2.

Install Control

1.

Can be mounted in any direction. 

2.

Mount so the gas flow is in the direction of the 

arrow on the bottom of the control.

NOTE:

Gas valve will leak if installed backwards. 

3.

Thread the pipe the amount shown in Table 5 for 

insertion into control or adapters. Do not thread 

pipe too far. Valve distortion or malfunction can 

result if the pipe is inserted too deeply.

4.

Apply a moderate amount of good quality pipe 

compound (do not use Teflon tape) only to the pipe, 

leaving two end threads bare. On LP installations, 

use a compound resistant to LP gas. See Fig. 1.

5.

Remove the seals over the control inlet and outlet if 

necessary.

6.

Connect the pipe to the control inlet and outlet. Use 

a wrench on the hex end of the control. See Fig. 3.

Table 5.  NPT Pipe Thread Length.

a

a

 All dimensions are in inches (mm). 

b

 OK when bushings are used.

Fig. 1. Use moderate amount of pipe compound.

Fig. 2.  Sediment trap installation.

Pipe 

Size

Thread Pipe 

this Amount

Maximum Depth Pipe can be 

inserted into Control

3/8

b

9/16 (14)

3/8 (9)

1/2

3/4 (19)

1/2 (13)

TWO IMPERFECT 

THREADS

GAS CONTROL

THREAD PIPE THE AMOUNT 

SHOWN IN TABLE FOR 

INSERTION INTO GAS CONTROL 

APPLY A MODERATE AMOUNT OF

PIPE COMPOUND TO PIPE ONLY

(LEAVE TWO END THREADS BARE).

M3075B

PIPE

GAS

CONTROL

GAS

CONTROL

HORIZONTAL

DROP

PIPED

GAS

SUPPLY

PIPED

GAS

SUPPLY

3 IN.

(76 MM)

MINIMUM

3 IN.

(76 MM)

MINIMUM

RISER

GAS

CONTROL

TUBING

GAS

SUPPLY

HORIZONTAL

DROP

3 IN.

(76 MM)

MINIMUM

RISER

M3077

2

1

2

2

1

2

ALL BENDS IN METALLIC TUBING SHOULD BE SMOOTH.

CAUTION:  SHUT OFF THE MAIN GAS SUPPLY BEFORE REMOVING

END CAP TO PREVENT GAS FROM FILLING THE WORK AREA.  TEST 

FOR GAS LEAKAGE WHEN INSTALLATION IS COMPLETE.

Summary of Contents for VR8215

Page 1: ...6 4 mm Body Pattern Straight through see Table 1 for inlet and outlet size Electrical Ratings Voltage and Frequency 24 Vac 50 60 Hz Current Draw Single Stage 0 5 A Field Wiring Single Stage Two 1 4 in...

Page 2: ...Dust or Grease Accumulation Heavy accumulations of dust or grease can cause the control to malfunction Where dust or grease can be a problem provide covers for the control to limit contamination Heat...

Page 3: ...d pipe that is free from chips If tubing is used make sure the ends are square deburred and clean All tubing bends must be smooth and without deformation 2 Run pipe or tubing to the control If tubing...

Page 4: ...valve label Fig 4 Typical wiring connections for 24 volt control in S87 Direct Ignition System Fig 5 Typical wiring connections with 24 volt control in S89 Direct Ignition System M27669A 24V 24V GND S...

Page 5: ...to main burner is properly adjusted for complete combustion Follow appliance manufacturer instructions 2 IF CHECKING GAS INPUT BY CLOCKING GAS METER Make certain there is no gas flow through the meter...

Page 6: ...sure all controls operate properly MAINTENANCE WARNING Fire or Explosion Hazard Can cause property damage severe injury or death Do not disassembly the gas control it contains no replaceable component...

Page 7: ...ctured gas Single Stage Single stage controls with standard and slow opening regulators model numbers with suffix S M T can be converted from one gas to the other with a conversion kit See Table 4 for...

Page 8: ...d the procedures outlined in your appliance manufacturer instructions can differ requiring special instructions To Turn ON Appliance STOP Read the Warnings Above Before Proceeding 1 The lighting seque...

Page 9: ...mm 1 4 po Configuration du corps passage direct reportez vous au Tableau 1 pour conna tre la taille d entr e et de sortie Caract ristiques lectriques Tension et fr quence 24 V c a 50 60 Hz Appel de co...

Page 10: ...tine vitez tout contact avec le r gulateur Lorsque des produits chimiques sont en suspension dans l air comme c est le cas dans le cadre de certaines applications industrielles ou agricoles prot gez l...

Page 11: ...ait tre expos des vapeurs de produits chimiques ou des gouttes d eau Installation de la tuyauterie sur le r gulateur Toute la tuyauterie doit tre conforme aux codes et r glements locaux ou au code nat...

Page 12: ...MM MINIMUM MONT E R GULATEUR DE GAZ ALIMENTATION EN GAZ TUBE HORIZONTAL MONT E MF3077C 2 1 2 2 1 2 TOUS LES COUDES DES TUBES M TALLIQUES DOIVENT TRE LISSES MISE EN GARDE COUPER L ARRIV E DE GAZ PRINC...

Page 13: ...le br leur principal est correctement r gl e pour assurer une combustion totale Suivez les instructions du fabricant de l appareil 2 POUR UNE V RIFICATION DE L ENTR E DE GAZ EN CHRONOM TRANT LE COMPT...

Page 14: ...ut causer des d g ts ou des blessures graves voire mortelles Ne d montez pas le r gulateur gaz car il ne contient pas de composants qui peuvent tre remplac s Toute tentative de d montage de r paration...

Page 15: ...n n cessaire de conversion Reportez vous au Tableau 4 pour plus d informations sur le num ro de pi ce du n cessaire de conversion correspondant 1 Coupez la vanne d alimentation en gaz de l appareil 2...

Page 16: ...c dures d finies par le fabricant de votre appareil peuvent diff rer et n cessiter des instructions sp ciales Pour mettre l appareil en marche ARR TEZ Lisez les avertissements ci dessus avant de conti...

Reviews: