4.2 Hydraulic characteristics
4.3 Materials
5
Installation
For the installation no special tools are required.Standard
heat and sanitary installer’s tools are sufficient.
5.1 Torque specification
5.2 Checking scope of delivery
•
Check delivery for completeness and integrity.
•
Unpack all parts.
•
Inform Resideo Technical Team if parts of the delivery
are damaged or missing.
•
Never install damaged parts.
5.3 Installation Guidelines
•
The installation site has to be frost-proof and the
protection of the device from chemicals, paints,
detergents, solvents and their vapours and
environmental influences must be guaranteed
•
The magnetic heating filter is not suited for:
– The separation of oils greases, solvents, soaps
and other lubricating media
– The separation of water
-
solvent materials
•
The magnetic heating filter is installed in the heating
circuit. For best performance we recommend to install
MHF49 in the return line of the heating circuit
downstream of the last radiator
•
If the circulating pump is installed in the return of the
heating circuit, please ensure that the filter is installed
upstream of the circulating pump
•
The heating system needs to be drained down before
installation
•
Installation, commissioning and maintenance may
only be performed by qualified personnel
•
Use the pipe cutter guide
•
The connection piece can be installed into both
horizontal and vertical pipework
•
The magnetic heating filter has to be installed with the
air vent pointing upwards
•
Make sure all seals are tight before filling the heating
system
•
Ensure good access for simple maintenance and
inspection
5.4 Installation
•
Read these installation instructions completely before
beginning the installation.
Carefully select the installation location of the MHF49
so that the MHF49 is easily accessible for cleaning
and maintenance.
•
Make certain that the heating system is standing idle
properly, the pump must be switched off (see
manufacturer’s instructions for the heating system).
•
Drain heating system and locate return pipe. Filter is
typically installed in the return pipe. Mark the section
to be cut out according to the cutting ruler and remove
the marked pipe section.
The cutting ruler you find on the packagingsleeve.
Connection size:
Kvs [m3/h]:
22 mm
6.50
28 mm
7.00
3/4" 6.80
1" 7.50
Component: Material:
Filter housing
Polyammide
Diverter body
Polyammide, glass-fibre reinforced
Ring
Polyammide, glass-fibre reinforced
Magnet housing
Polyammide, glass-fibre reinforced
Filter mesh
Stainless steel
Gasket EPDM
Magnet
NeodymiumB (Tmax) / B (Tamb) <
1%(when: Tmax = 130 °C, Tamb =
21 °C)Tested according to
IEC60404-5 & ASTM A977
Number: Torque
specification:
1 Hand
tight
2
Max. 1 Nm
3
Max. 18 Nm ±10 %
Designation: Count:
MHF49 1
Installation instructions
1
Cutting ruler (included on the
packaging sleeve)
1