Mark the length of the pipe section to be removed
using the cutting ruler on the edge of the packaging
sleeve at hand.
•
Make sure there is adequate room to rotate the filter
and access it for cleaning purposes.
Installation of filter connection
1.
Connection thread
2.
washer
3.
Isolation valve
•
Fit the isolation valve using the compression fittings
and rings provided. Ensure correct assembly and do
not make watertight yet.
Check flow direction
1.
Diverter body
•
Check flow arrow direction on diverter body and
ensure it is the same as the pipe work flow direction.
•
Fit diverter body using flat washers provided.
•
Tighten water tight using spanner.
•
Position the diverter valve including the isolation valve
correctly.
•
Make the compression connections water tight.
Assemble MHF49
1.
MHF49
2.
Large fastening ring
3.
Lock ring
4.
O-ring
5.
Diverter
•
Fasten MHF49 [1].
•
Adjust mounting position vertically.
•
Make certain that the O-ring [3] is correctly positioned.
•
Tighten the large fastening ring [2] hand tight.
•
Filter body must be installed vertically as shown.
•
Unscrew the air vent cap from the top of the filter
housing. Open only the inlet isolation valve until water
exits the air vent hole.
•
Close the isolation valve.
•
Screw the the air vent cap back on water tight.
•
Open both isolation valves.
6
Cleaning / Maintenance
6.1 Cleaning cycle
•
Before the beginning of each heating period
•
For every maintenance of the heating system
•
In case of heating system malfunctions
1
2
3
4
5