6.2 Cleaning the magnet housing

1.

MHF49

2.

O-ring

3.

Filter mesh

4.

Removeable sheath

5.

Sealing ring

6.

Housing end cap

Make certain that the heating system is standing idle 
properly, the pump must be switched off (see 
manufacturer’s instructions for the heating system).

Close both isolation valves.

CAUTION!

Warning against hot water!
Hot water may cause burns.
When removing housing end cap hold abucket 
below the filter to catch the exitingwater and debris.

Remove housing end cap [6].

Clean magnetic filter.

Screw the housing end cap [6] back on, applying a 
torque of maximum 18 Nm ±10 %.

Make certain that the O-ring [2] is correctly positioned.

Unscrew the air vent cap from the top of the filter 
housing. Open only the inlet isolation valve until water 
exits the air vent hole.

Close the isolation valve.

Screw the air vent cap back on water tight.

Open both isolation valves.

7

Spare Parts

For the MHF49 there are no designated spare parts. In 
normal operation no spare parts are needed. In case of 
damage the whole MHF49 must be replaced.

8

Disposal

Both the MHF49 and the associated packaging consist mostly 
of recyclable raw materials.

Dispose of packing and all recyclable materials 
separately, properly and in an environmentally friendly 
way.

1

2

3

4

5

6

Summary of Contents for Braukmann MHF49

Page 1: ...R32347453 001 Rev A Braukmann MHF49 Installation instructions Einbauanleitung Refilling Combination Nachfüllkombination ...

Page 2: ...iption of Function 3 4 Technical Data 4 5 Installation 5 6 Cleaning Maintenance 6 7 Spare Parts 7 8 Disposal 7 D 1 Allgemeine Informationen8 2 Sicherheitshinweise 8 3 Funktionsbeschreibung 8 4 Technische Daten 9 5 Montage 10 6 Reinigung Wartung 13 7 Ersatzteile 13 8 Entsorgung 13 ...

Page 3: ... the product are not allowed Only use original spare parts and accessories for repairs or replacement 2 1 Intended use The MHF49 was built according to the state of the art and recognized safety regulations However damage to property may arise from improper or unintended use The MHF49 is built into the heating circuit and is intended to filter out residue in order to prevent premature wear or fail...

Page 4: ...the filter During maintenance in order to easily clean the magnet housing remove the sheath and clean it In the first instance the boiler is protected against damage from impurities The MHF49 is most effective when it is installed at these positions in the heating circuit In the return flow downstream of the last radiator but upstream of the circulation pump Especially at start up to protect the b...

Page 5: ...sonnel Use the pipe cutter guide The connection piece can be installed into both horizontal and vertical pipework The magnetic heating filter has to be installed with the air vent pointing upwards Make sure all seals are tight before filling the heating system Ensure good access for simple maintenance and inspection 5 4 Installation Read these installation instructions completely before beginning ...

Page 6: ...ten water tight using spanner Position the diverter valve including the isolation valve correctly Make the compression connections water tight Assemble MHF49 1 MHF49 2 Large fastening ring 3 Lock ring 4 O ring 5 Diverter Fasten MHF49 1 Adjust mounting position vertically Make certain that the O ring 3 is correctly positioned Tighten the large fastening ring 2 hand tight Filter body must be install...

Page 7: ...the housing end cap 6 back on applying a torque of maximum 18 Nm 10 Make certain that the O ring 2 is correctly positioned Unscrew the air vent cap from the top of the filter housing Open only the inlet isolation valve until water exits the air vent hole Close the isolation valve Screw the air vent cap back on water tight Open both isolation valves 7 Spare Parts For the MHF49 there are no designat...

Page 8: ...rf nur von qualifiziertem Personal durchgeführt werden Fehler müssen sofort behoben werden Unberechtigte Änderungen am Produkt sind nicht zulässig Verwenden Sie nur Originalersatzteile und Originalzubehör für Reparaturen oder Austausch 2 1 Bestimmungsgemäße Verwendung Der MHF49 wurde gemäß den aktuellsten und anerkannten Sicherheitsvorschriften hergestellt Bei unsachgemäßer oder missbräuchlicher V...

Page 9: ...lust gering zu halten durch geringen hydraulischen Widerstand womit dem Medium ein bestimmter Pfad vorgegeben wird was dazu beiträgt dass schwere Unreinheiten an den Filterboden gezogen werden Zur leichten Reinigung des Magnetgehäuses entfernen Sie bei der Wartung den Mantel und reinigen ihn In erster Linie wird der Boiler vor Schäden durch Verunreinigungen geschützt Der MHF49 arbeitet am effektiv...

Page 10: ...onstigen schmierenden Medien zur Abscheidung wasserlöslicher Stoffe Der magnetische Heizungsfilter wird im Heizkreislauf installiert Für eine optimale Leistung empfehlen wir die Installation des MHF49 in der Rücklaufleitung nach dem letzten Heizkörper Wenn die Umwälzpumpe im Rücklauf des Heizkreises installiert ist stellen Sie sicher dass der Filter vor der Umwälzpumpe installiert wird Vor der Ins...

Page 11: ...Markieren Sie mithilfe der Schneideschablone den auszuschneidenden Abschnitt und entfernen Sie den markierten Rohrabschnitt Die Schneideschablone ist Teil der Verpackung Markieren Sie die Länge des Rohrabschnitts das Sie entfernen möchten mithilfe der Schablone die sich an der Kante der vorliegenden Verpackung befindet Stellen Sie sicher dass Sie über ausreichend Platz verfügen um den Filter drehe...

Page 12: ...n Sie beide Absperrarmaturen VORSICHT Warnung vor heißem Wasser Heißes Wasser kann zu Verbrennungen führen Halten Sie beim Entfernen der Endkappe des Gehäuses einen Eimer unter den Filter um austretendes Wasser und Schmutz aufzufangen Entfernen Sie die Endkappe des Gehäuses 6 Reinigen Sie den Magnetfilter Schrauben Sie die Endkappe des Gehäuses 6 wieder auf verwenden Sie dazu ein maximales Drehmom...

Page 13: ...D MU1H 1555GE23 R0420 13 ...

Page 14: ...erland by its authorised representative Ademco 1 GmbH 2020 Resideo Technologies Inc All rights reserved For more information homecomfort resideo com europe Ademco 1 GmbH Hardhofweg 40 74821 MOSBACH GERMANY Phone 49 6261 810 Fax 49 6261 81309 Subject to change MU1H 1555GE23 R0420 ...

Reviews: