1. INTRODUCTION 

1.1 General Description 

The continuity of electrical power is an essential requirement for critical load 

operations .The Uninterruptible Power System (UPS) is designed to meet the 

user‘s need of present computer, server and the equipment of office 

automation that make the UPS more compact and less noisy. 

To choose the UPS as your equipment protector is a wise investment 

because it supplies reliable, pure and stable power at affordable price. 

1.2 Key features 

1. Multiple microprocessor and double-conversion design base. 

2. Wide input range designed to operate under harsh environment.   

3. High input power factor and DC-start function. 

4. LED and LCD display for detail status and data; real-time alarm silence. 

5. Enhanced protections against light, surges, and disturbance etc. 

6. Remote monitoring with SNMP intelligent slot and RS-232 interface. 

7. Light weight and compact size, easy to transport and place. 

 

 

1.3 Important Notices 

To be sure that the UPS will be operated correctly, the following items should 

be noticed: 

 

3

1. Read instructions carefully before operating the UPS. 

2. UPS power connect instruction should be followed. 

3. Please don‘t open the case to prevent danger. 

4. If the UPS will be stored for long period, the battery must be charged once 

every 90 days. 

5. Retain the load within the rating of UPS to prevent faults. 

6. Handle unusual events according to the trouble-shooting guide. 

7. Keep the UPS clean and dry. 

2. SAFTY INSTRUCTION 

2.1 Transporting 

1. Disconnect all power cables if necessary. 

2. Be careful not to damage the UPS while transporting. 

3. Don‘t move the UPS upside down. 

4. Please transport the UPS system only in the original packaging (to protect 

against shock and impact). 

2.2 Positioning 

1. Do not put the UPS on rugged or declined surface. 

2. Do not install the UPS system near water or in damp environments. 

3. Do not install the UPS system where it would be exposed to direct sunlight 

or near heat. 

Summary of Contents for RP-UPH

Page 1: ...rruptible Power Supply 1 CONTENTS 1 INTRODUCTION 2 2 SAFTY INSTRUCTION 3 3 SYSTEM DESCRIPTION 6 4 CABLE CONNECTION 14 5 OPERATION 15 6 TROUBLE SHOOTING GUIDE 21 7 OPERATION MODES OF THE UPS 24 8 COMPU...

Page 2: ...weight and compact size easy to transport and place 1 3 Important Notices To be sure that the UPS will be operated correctly the following items should be noticed 3 1 Read instructions carefully befo...

Page 3: ...ds or other foreign objects can enter the UPS system 5 2 5 Maintenance and Service 1 Caution risk of electric shock Even after the unit is disconnected from the mains power supply building wiring sock...

Page 4: ...ect Down key 3 It is pressed to select downward the UPS status on LCD Display 7 Display Function LCD Display 1 This indicates the UPS operation information including UPS status input output voltage in...

Page 5: ...8 2KVA 3KVA Tower Case 9 1KVA 2KVA 3KVA Rack Mount Case...

Page 6: ...e Protection 8 Breaker 4 Remote Control Detachable LCD Panel Option 9 Input Socket 5 Output Socket NEMA or IEC 11 1KVA Rack Mount Case 1 Fax Modem Surge Protection 6 Input Socket 2 DB 9 RS 232 Interfa...

Page 7: ...tion 9 Breaker 5 Output Socket NEMA or IEC 10 Input Socket 13 2KVA 3KVA Rack Mount Case 1 Breaker 7 DB 9 RS 232 Interface Port 2 Remote Control Detachable LCD Panel Option 8 Input Socket 3 External Ba...

Page 8: ...is model is with socket types only NEMA or IEC Simply plug the load power cord to the output sockets to complete connection 15 5 Operation 5 1 Check Prior to Start Up 1 Ensure the UPS is in a suitable...

Page 9: ...S is stored over 3 months please keep supplying power to the UPS for at least 24 hours to ensure battery fully recharged 5 4 LCD Display Use Up Down key to select menu displays of the LCD described be...

Page 10: ...w and HI high In this screen press on off Control Key to enter the following steps for LO HI voltage setting B The cursor will pop up to indicate the item newly selected Press on off Control Key to ge...

Page 11: ...ected press on off Control Key again to save the data 21 6 Trouble Shooting Due to careful design and strict tests of our products fail of UPS seldom occurs However once they do fail in some situation...

Page 12: ...per 0 5 second Please reduce the critical load to 100 23 5 AC utility power is normal but the load is supplied by AC utility power via bypass Output power is more than 150 Warning LED lits up and buz...

Page 13: ...DC AC inverter and static switch to support power to load The battery charging voltage comes from AC utility input and converted by AC DC charger to support battery charging power 25 7 3 AC Utility Fa...

Page 14: ...pply RS 232 for monitoring software like RUPSII or UPSilon 2000 of Megatec Company The UPS communicates with the computer by sending out RS 232 data streams to one of the serial ports By this method t...

Page 15: ...465 200 352 465 200 352 Specifications are subject to change without notice 9 SPECIFICATIONS 29 9 2 Tower Case 120V Rated Power Capacity 1KVA 700W 1 5KVA 1050W 3KVA 2100W Input Voltage 60 138VAC Base...

Page 16: ...8 Specifications are subject to change without notice 31 9 4 Rack Mount Case 120V Rated Power Capacity 1KVA 700W 1 5KVA 1050W 3KVA 2100W Input Voltage 60 138VAC Base on load percentage 110 70 60 50 50...

Page 17: ...32...

Reviews: