Unit Operation
3.1 Status view
The status view is the first page you see when accessing the web
GUI of a Trinity-300 series unit. This page gives you a fast
overview of the link and unit status.
Figure 11 – Status view.
Graphical status indicators
The upper part of the status view holds a number of graphical status indicators
(see figure below). The Ethernet and Radio link status are
displayed in the upper left corner. An indication bar shows if the
unit is a Master or a Client and gives the connectivity status.
The Link qualities for the two antenna branches are also shown,
both graphically and as two dBm (and RSSI) values. The dBm
values show the actual signal strength as measured by the
equipment while the RSSI level is measured as the difference in
received signal strength and noise floor level.
Repeatit’s Deployment Guideline explains how to interpret the
signal levels and how to install antennas so the link quality is
optimized. The two chains should have similar (+/- two-three dB)
signal strength if antenna alignment has been done
successfully.