15
Emergency Backup
Recommended Accessories
*Reliance Controls 306A Pro/
Tran 2 Manual Transfer Switch
*NEMA TT-30P to
NEMA L14-30R Adapter Cable
METER 1
METER 2
GEN
OFF
GEN
OFF
LINE
LINE
A
B
C
D
E
F
z
For a safe and reliable
installation, it is
recommended that the
installation be carried out
by a trained and licensed
electrician.
z
Please read the user
manual of the Transfer
Switch carefully before
installation.
I/ON
O/OFF
ON
OFF
STEP-6.1
I/ON
O/OFF
A
METER 1
METER 2
GEN
OFF
LINE
GEN
OFF
LINE
B
C
D
E
F
1
2
1
2
1
2
I/ON
O/OFF
STEP-6.2
N
N
PE
Push the switches toward the sides
of the AC load center to open all
the AC circuit breakers. Remove
the cover of the AC load center.
Connect the bare wires from the Transfer Switch (sold separately)
to the AC load center. The white neutral wire goes to the neutral
busbar (N), and the green ground wire goes to the grounding
busbar (PE).
I/ON
O/OFF
STEP-6.3
A
METER 1
METER 2
GEN
OFF
LINE
GEN
OFF
LINE
B
C
D
E
F
1
2
1
2
1
2
I/ON
O/OFF
STEP-6.4
Branch Line (C) Wiring Diagram
Determine the 120VAC circuits
that need to be used during an
emergency. Disconnect the black
live wires from the corresponding
AC branch circuit breakers.
Find the red and black wires from the Transfer Switch that are marked
C, D, E, and F. Connect the red wires to the selected AC branch circuit
breakers. Insert the black wires marked the same letter and the black
live wires disconnected from the AC branch circuit breakers into wire
ceonnectors (not included). Twist the wire connectors tightly.
Powering Appliances